GDC Group Brazilia F 5 Installation And Owner'S Manual Download Page 23

23

Control Knob

Fig. 3

Relative positions of markings on

side of upper knob.

Position       - OFF

Position       - IGNITION

Position       - LOW

Position       - HIGH

Fig. 3b

Fig. 3a

Owner Guide

2.0 Introduction & Operation

2.3

Operating units fitted with the

Comfortstat control. 

1. The appliance is controlled by two knobs

which are positioned at the lower right on the

front of case (Fig. 3). 

The upper knob has four positions.

2. 

To light the appliance 

(Fig 3a): At the OFF 

(   ) position push the upper control knob as far

as possible and still pushing in 

slowly

turn

anti-clockwise to the ignition position (    ) to light

the burner. Turning the control knob slowly

allows gas to enter the burner ready for ignition.

Keep the knob pushed in for 10 seconds and the

burner should remain alight. If not, repeat the

sequence.

NOTE:

Under extreme wind conditions more

than one attempt to light the appliance may

be required.

3. Once lit, the control knob can be altered to the

High or Low heat settings.    

4. When first lit after installation some smells are

likely to be emitted. These will quickly clear away

with use.

NOTE:

If the appliance goes out at any time

wait 3 minutes and repeat the procedure.

When changing from one setting to another

the knob should always be pushed in slightly.

5. 

To adjust the thermostat setting 

(Fig 3b)

:

The lower control knob alters the temperature

setting, the knob has seven positions.

6. 

To turn the appliance off:

Push the knob in

slightly and turn to the OFF (   ) position.

Position
Position
Position
Position

OFF

IGNITION

LOW

HIGH

Markings on lower knob.

Summary of Contents for Brazilia F 5

Page 1: ...omfortstat 2 F 8ST Balanced Flue Gas Wall Heaters Installation and Owner Guide Please leave these instructions with the user 5131922 06 Brazilia F 5 Brazilia F 5S Brazilia F 8ST Comfortstat 2 Brazilia...

Page 2: ...m or database or transmitted in any form or by any means whether electronic mechanical recording or otherwise without the prior written permission of the copyright owner Applications for the copyright...

Page 3: ...roubleshooting 26 6 0 Warranty Service 27 28 7 0 Warning 27 Section Page s Contents Installer Before continuing any further with the installation of this appliance please read the following guide to m...

Page 4: ...d flue arrangement Except for Comfortstat the appliance is controlled by a control knob which operates the ignition and alters the heat output The control knob has five positions giving a choice of th...

Page 5: ...ons Failure to install the appliance correctly could lead to prosecution GAS SAFE REGISTER and CORGI require their members to work to recognised standards In the United Kingdom the installation must a...

Page 6: ...ols Rotary thermostat allowing Comfortstat a lowt position and adjustment between low and high temperature settings Flame failure device Thermocouple Output 8 13mv Heat Exchanger Cast Iron 2 0 Technic...

Page 7: ...device Thermocouple Output 8 13mv Heat Exchanger Cast Iron 2 0 Technical Data F 5 F 5S Propane When converted using kit No 5110284 Category of Appliance II2H3P The appliance is set for Gas Type G31 at...

Page 8: ...de for Gas Installations in Timber Framed Dwellings 3 2 Clearances 1 The appliance must be fitted on a vertical flat non combustible wall Any combustible wall coverings should be removed from within t...

Page 9: ...capable of being opened or any ventilation inlet or similar opening no part of the terminal shall be within 300mm 1 ft measured vertically from the bottom of the opening b Where the flue terminal of...

Page 10: ...ntended for use in habitable rooms and must not be fitted in cupboards or confined compartments 3 6 Gas Supply 1 The inlet connection is located on the gas tap at the bottom right hand side of the app...

Page 11: ...20mm 3 4in Adjust the distance from the back of the airbox and the joint between the terminal and air duct to this dimension Using the length of flue tape provided fix this dimension by taping up the...

Page 12: ...ide are completed 1 Push in and turn the control knob back to the OFF position 2 On models not fitted with the Comfortstat control remove the knob from the appliance by gently pulling the knob forward...

Page 13: ...xchanger casting If necessary clean the viewing window 14 With a light brush carefully remove deposits from the spark electrode burner flame ports and the burner gauze Fig 17 15 Replace the rope seal...

Page 14: ...studs 2 Remove the three screws holding the burner retaining plate to the airbox and undo the thermocouple nut from the gas tap Fig 23 25 3 Ease the thermocouple and electrode leads from the rubber g...

Page 15: ...ry aeration hole Fig 27 8 Reassemble in reverse order of dismantling 7 5 Injector 1 Remove the burner as described in sections 7 4 1 to 7 4 4 2 Undo the injector and sealing washer retaining the washe...

Page 16: ...d undo the thermocouple nut from the gas tap Fig 31 33 3 Ease the thermocouple and electrode leads from the rubber grommet Fig 32 4 Disengage the burner from the injector and pull the electrode lead o...

Page 17: ...to the burner inlet ensuring that it covers the primary aeration hole Fig 35 8 Reassemble in reverse order of dismantling 8 4 Injector 1 Remove the burner as described in sections 8 3 1 to 8 3 4 2 Und...

Page 18: ...18 8 0 Fault Finding 3 5 0 5mm 7 1 5mm Fig 38 Ensure all installation criteria have been satisfied before performing Fault Finding e g flue terminal position Installer Guide...

Page 19: ...enerator 042941 I 381941 Injector F 5 F 5S 224047 J 381942 Injector F 8S F 8ST 224104 K 205791 Washer For injector 082365 L 205844 Insulation F 5 F 5S 224048 M E01359 Insulation F 8S F 8ST 223971 N 15...

Page 20: ...Owner Guide Brazilia F 5 Brazilia F 5S Brazilia F 8ST Comfortstat 2 Brazilia F 8S...

Page 21: ...covering adjacent to any heating appliance The likelihood of wall staining from convected air currents will be increased in environments where high levels of tobacco smoke or other contaminants exist...

Page 22: ...gas to enter the burner ready for ignition Keep the knob pushed in for 20 seconds and the burner should remain alight If not repeat the sequence NOTE Under extreme wind conditions more than one attem...

Page 23: ...gnition Keep the knob pushed in for 10 seconds and the burner should remain alight If not repeat the sequence NOTE Under extreme wind conditions more than one attempt to light the appliance may be req...

Page 24: ...lish 3 2 Clearances 1 Internally the appliance must not be fitted under a shelf or sill that projects more than 150mm 6in 2 Curtains or a shelf must not be closer to the top of the outer case than 140...

Page 25: ...ed for customers suffering from arthritis or similar conditions and provides the user with extra leverage when operating the control knob It is available from Spares Stockists 4 2 Running Costs 1 The...

Page 26: ...ol knob not fully pushed in for sufficient period of time Keep the control knob pushed in for 20 secs and the burner should remain alight If not repeat the sequence Cold Start Up of Appliance Extreme...

Page 27: ...ave the following information to hand 1 Fire serial number and fascia code Located on the information label See figure 4 on page 27 2 Date of installation 3 Your installer name and address details 4 F...

Page 28: ...staller Details Block Capitals Installer Name Gas Safe Register or Corgi Registration Number Company Name Company Address Company Telephone number Company Fax number Owner Guide Information label loca...

Reviews: