DU-PH-0062-01 Rev A 8/10/07 GCX Corp Page 2 of 4 

Mounting on Post 

1.  Clamp PRC onto post as shown and tighten Clamping Knob. 

Mount monitor according to Philips instructions.  

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Mounting Docking Station and Power Supply on Rail 

Installation Note:

 Docking station must attached to Mounting Bracket before PRC is rotated. See page 1, step 1 for 

attachment of docking station. Power supply attachment is same as page 1, step 2. 

 

1.  Unscrew PRC from Mounting Bracket (not shown), rotate Clamping Knob 90º (Knob pointing upward) and re-attach to 

Mounting Bracket as shown below. 

 

2.  Hook PRC over rail and tighten Clamping Knob (below right). 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Unscrew PRC, rotate to position shown, and re-attach to 
Mounting Bracket. 

 

Installation Note:

 Docking Station Must Be Attached to 

Mounting Bracket before rotating PRC. 

See page 1, step 2 for attachment of 
power supply to Mounting Bracket. 

Summary of Contents for PH-0062-01

Page 1: ...e not shown Tools Required Phillips screwdriver not provided Mounting Docking Station and Power Supply on a Post 1 Fasten docking station to Mounting Bracket with two 2 M4 x 14 mm PHMS as show below left 2 Fasten power supply to bottom of Mounting Bracket with two 2 M4 x 10 mm PHMS as shown below right Item Description Qty 1 Mounting Bracket PRC Assembly 1 2 M4 x 14 mm Pan Head Machine Screw PHMS ...

Page 2: ...1 step 1 for attachment of docking station Power supply attachment is same as page 1 step 2 1 Unscrew PRC from Mounting Bracket not shown rotate Clamping Knob 90º Knob pointing upward and re attach to Mounting Bracket as shown below 2 Hook PRC over rail and tighten Clamping Knob below right Unscrew PRC rotate to position shown and re attach to Mounting Bracket Installation Note Docking Station Mus...

Page 3: ...Fasten Mounting Bracket to Channel Mount with four 4 M4 x 10 mm FHMS as shown below 2 Fasten docking station to Mounting Bracket with two 2 M4 x 14 mm PHMS as shown right 3 Fasten power supply to Mounting Bracket with two 2 M4 x 10 mm PHMS as shown right M4 x 10 mm FHMS 4 Channel Mount Mounting Bracket M4 x 10 mm PHMS 2 M4 x 14 mm PHMS 2 ...

Page 4: ...t refer to the specific instructions delivered with those products 1 The mounting assembly may be cleaned with most mild non abrasive solutions commonly used in the hospital environment e g diluted bleach ammonia or alcohol solutions 2 The surface finish will be permanently damaged by strong chemicals and solvents such as acetone and trichloroethylene 3 Do not use steel wool or other abrasive mate...

Reviews: