![GBS Mini 200 Starter Kit User Manual Download Page 42](http://html1.mh-extra.com/html/gbs/mini-200-starter-kit/mini-200-starter-kit_user-manual_3849996042.webp)
mini 200
Starter Kit
42
Step 1
Connect Device C to the network card of a PC.
Step 2
Open the Utility. The Main tab page displays information about Device C after connection
succeeds. Second Step of chapter 6.2.
Step 3
Click the Privacy tab page. Enter a name in the Private Network Name field. Third Step of
chapter 6.2.
Step 4
Click Set Local Device Only. When the page as shown in Fourth step of chapter 6.2, the
setting succeeds. Now Device C has been removed from its logical network.
Step 5
Press the pushbutton on Device A or B for less than 3 seconds, making it the ‘adder’.
Step 6
Within 2 minutes, press the pushbutton on Device C (the ‘joiner’) for less than 3 seconds.
Step 7
Wait for connection to complete.
The Power indicator on Device A (or Device B) and Device C will flash at 1 second intervals until
the process succeeds or fails. It will illuminate steadily on success. If an error occurs, the Power
indicator on Device A (or Device B) and Device C will flash unevenly for 2 minutes.
8 How to Improve the Transmission Capacity
It is important to use the PLC product complying with the following “correct rules”, because it can
significantly improve the transmission c apacity of the network.
It is recommended to plug the device directly into a wall socket, not to power stripe.