4.0 INTERFACE PROTOCOLS 

 

The  GBA  ST2  can  communicate  with  a  host  (machine)  via  one  of  five  base  interface  protocols.  
These  protocols  are;  NAMA  MDB,  pulse,  parallel,  cctalk

®

  and  bi-directional  serial  (“RS232”).  

Variants  to  some  of  these  protocols  are  also  available,  please  contact  your  regional  office  for 
further details. 

 

The  product  is  connected  to  the  host  using  an  appropriate  interface  cable  assembly.  With  the 
exception  of  MDB  the  GBA  ST2  will  be  connected  to  the  host  machine  using  a  cable  assembly 
terminated with a 20-way connector, as denoted in section 8.0 – Electrical Connections. 

 

4.1 NAMA MDB 

 

If the GBA ST2 is used in an MDB interface application, an additional interface cable assembly is 
required  to  connect  to  a  standard  NAMA  6  pin  connector.    Please  contact  Technical  Support  for 
details. 

 

4.2 CCTALK

®

 INTERFACE 

 

If the validator is used in a ccTalk

®

 interface application, an alternative 20 pin harness is required. 

Part Number: ASY-W-10265.  
Please contact Technical Support for details. 

 
 

For  further  details  relating  to  the  operation  of  specific  interfaces  please  refer  to  the  Interface 
Description Manual. 

Summary of Contents for ST2

Page 1: ...GBA Global Bill Acceptors GBA ST2 Operations Manual Page 1 of 25 Astrosys International Ltd January 2009 GBA ST2 Op Manual V1 01 GBA ST2 Operations Manual...

Page 2: ...ng and Removal 6 Note Guide Plate Fitting and Removal 6 Interface Protocols 7 NAMA MDB 7 ccTalk 7 Software Configuration 8 On Board Push Button 8 PC Based Tools 9 USB Download 11 Software Configuratio...

Page 3: ...ations previously served by the GBA stacker less product range It is also designed for the rigours of the amusement and gaming markets and can be used in all applications The following features are al...

Page 4: ...up to 170 mm long Bill Acceptance Rate Typically greater than 98 Cycle Time for Validation Approximately 2 seconds Interface Protocols Supported Pulse Parallel cctalk plain encrypted bi direction seri...

Page 5: ...t appropriate design for your currency please contact your local regional office 2 3 2 Faceplate Bezel options Faceplates and bezels are available in four styles to suit the host machine please see de...

Page 6: ...de fitting 3 1 2 Note Guide Fitting Removal Refer figure 3 1 2 To remove the note guide first remove the faceplate bezel Push together the two sides of the note guide and pull away from the validator...

Page 7: ...assembly With the exception of MDB the GBA ST2 will be connected to the host machine using a cable assembly terminated with a 20 way connector as denoted in section 8 0 Electrical Connections 4 1 NAMA...

Page 8: ...disable modes a sample note must then be presented for scanning If the operation is successful the validator will return to normal operation mode If it is unsuccessful it will remain in the program mo...

Page 9: ...2 is not a necessity it is recommended periodically for preventative maintenance and also after any change to the software configuration of the unit Equipment Required Calibration Paper Procedure 1 Th...

Page 10: ...or firmware has been changed or following modification to the configuration of the unit via a programming card or GBATalk Tools In general re calibration of the unit should be carried out once every 6...

Page 11: ...ng either the GBATalk PC program or Program Card facility as mentioned above Two kinds of program card are available Firstly a card to set all options all options must be specified and secondly indivi...

Page 12: ...r checks at start up This mode is designed to enable the GBA ST2 to be used in battery applications It is anticipated that the unit is powered up only when a customer wants to present a note e g by li...

Page 13: ...This option can be set from 0 to 255 and determines the time in minutes that the validator is disabled following the detection of the set number of successive OASG rejects If this option is set to ze...

Page 14: ...ecurity incident has been reported GBA ST2 DEFAULT SETTING GUIDELINES Note The GBA ST2 can be configured in many ways allowing the user to customize the unit to their specific requirements The configu...

Page 15: ...r Consumption Quiescent 200mA Validating 800mA Stalled 1 4A Maximum Output Low Voltage 0 4VDC Minimum Output High Voltage 2 4VDC Maximum output sink current 50mA 12VDC Open collector Input pull up to...

Page 16: ...s is required Part Number HCC Please contact Technical Support for details MDB Connection If the validator is used in an MDB interface application an additional power supply or conversion board is req...

Page 17: ...c 9 Whi Blk Grn n c n c n c RXD 10 Blue Inhibit Control Input Enable Inhibit Control Input Enable Inhibit Control Input Enable n c 11 Violet Vend 1 Output Confirm Signal To Start Serial CTS n c n c 1...

Page 18: ...cted selects pulse mode BUSY Output a low output indicates when the acceptor is operating DATA Output used to send data to the host machine CTS Input from host that tells acceptor that host is ready t...

Page 19: ...nlatch and then gently pivot top section backwards to open and remove 4 Using the Cotton swab or cloth dipped in the cleaning solution carefully clean all sensors and plastic windows using light force...

Page 20: ...sonnel when assisting customers over the phone or by email Normal Run Mode The LED will be permanently Green solid on If a note is rejected a flash code is given Green LED Flashed off If the note is r...

Page 21: ...programmed notes are rejected 1 Acceptance inhibited for all notes 2 MASG not working 3 Escrow sensor not working 1 Software configuration 2 Internal MASG 1 Use on board button or GBA Talk to enable...

Page 22: ...GBA Global Bill Acceptors GBA ST2 Operations Manual Page 22 of 25 Astrosys International Ltd January 2009 GBA ST2 Op Manual V1 01 GBA ST2 DIMENSIONS WITH COMPACT BEZEL...

Page 23: ...GBA Global Bill Acceptors GBA ST2 Operations Manual Page 23 of 25 Astrosys International Ltd January 2009 GBA ST2 Op Manual V1 01 GBA ST2 DIMENSIONS WITH STANDARD BEZEL...

Page 24: ...GBA Global Bill Acceptors GBA ST2 Operations Manual Page 24 of 25 Astrosys International Ltd January 2009 GBA ST2 Op Manual V1 01 GBA ST2 DIMENSIONS WITH STANDARD FACEPLATE...

Page 25: ...chnology Park 63 85 Turner Street Wantage Port Melbourne Oxon OX12 9FA Victoria 3207 U K Australia Tel 44 0 1235 772201 Tel 613 9646 6446 Fax 44 0 1235 772202 Fax 613 9646 6447 E Mail sales astrosyste...

Reviews: