5.3 USB FLASH DOWNLOAD REPROGRAMMING
5.3 - image of USB input
Equipment Required:
USB memory stick
Procedure:
1. Ensure the supply to the validator is switched OFF.
2. Connect the USB memory stick with the required noteset file stored in it
3. The ST2 will automatically download the file and reprogram itself.
4. During this process the LED will rapidly alternate between Green and Red. Upon
completion the LED will revert to a solid Green state.
5. Once the process is complete simply remove the USB memory stick and recalibrate the unit
5.4 SOFTWARE CONFIGURATION OPTIONS:
All of the software options below can be set using either the GBATalk PC program or Program
Card facility, as mentioned above. Two kinds of program card are available. Firstly a card to set all
options (all options must be specified) and secondly individual, specific option cards that will set
only key options such as security level, ccTalk
®
Encryption Key or Note enable / disable.
Use Magnetic Sensor
Selectable for units fitted with a magnetic reader head, in combination with software containing “C”
denotation, e.g., ST299
C
0419.100.
Interface:
The GBA ST2 can be set for use with the following interfaces:
(1) Pulse
(2) Parallel
(3) RS232
(4) MDB
1
(5) ccTalk
®
Non Encrypted
2
(6) ccTalk
®
Encrypted
3
1
Note: MDB interface requires the use of a dedicated interface harness to connect to a standard NAMA 6 pin
connector. Please contact your distributor or regional office for details.
2
Note: ccTalk
®
interface requires the use of a dedicated interface harness. Please contact your distributor or