background image

GBA

 

Global Bill Acceptors

 

                             

GBA ST2 

 Operations Manual

 

 

Page 5 of 25 

Astrosys International Ltd 

January 2009 

GBA ST2 Op Manual V1.01 

2.3 Build Options 

2.3.1 Note Guide  

 

Note guides are available in an illuminated, flashing style.  The note guide can be configured in a 
number of options, to provide specific information to the user / technician.  Note guides of specific 
widths are fixed to the note guide common assembly and to the internal path of the lower sensor 
assembly, to suit particular currencies.  For information about the most appropriate design for your 
currency please contact your local regional office.   
 

2.3.2 Faceplate / Bezel options 

 

Faceplates  and  bezels  are  available  in  four  styles,  to  suit  the  host  machine,  please  see  details 
below.    Please  note  that  for  currencies  containing  note  denominations  over  82mm,  the  Wide 
Compact Bezel must be used.

  

 

 

 

 

   

 

 

 

 

 

2.3.3 Standard Faceplate 

 

 

2.3.3 Compact Bezel 

 

 

 

 

 

   

 

 

2.3.3 Standard Bezel 

 

 

2.3.3 Wide Compact Bezel 

 

2.3.4 Interface Cable Assembly 

 

The GBA ST2 is fitted with a 20 pin interface connector.  All interfaces, with the exception of NAMA 
MDB,  utilise  this  connector  for  communication  to  a  host  machine.    For  further  details  relating  to 
interface and connection information, please refer to section 8.0 – Electrical Connections. 

 

Summary of Contents for ST2

Page 1: ...GBA Global Bill Acceptors GBA ST2 Operations Manual Page 1 of 25 Astrosys International Ltd January 2009 GBA ST2 Op Manual V1 01 GBA ST2 Operations Manual...

Page 2: ...ng and Removal 6 Note Guide Plate Fitting and Removal 6 Interface Protocols 7 NAMA MDB 7 ccTalk 7 Software Configuration 8 On Board Push Button 8 PC Based Tools 9 USB Download 11 Software Configuratio...

Page 3: ...ations previously served by the GBA stacker less product range It is also designed for the rigours of the amusement and gaming markets and can be used in all applications The following features are al...

Page 4: ...up to 170 mm long Bill Acceptance Rate Typically greater than 98 Cycle Time for Validation Approximately 2 seconds Interface Protocols Supported Pulse Parallel cctalk plain encrypted bi direction seri...

Page 5: ...t appropriate design for your currency please contact your local regional office 2 3 2 Faceplate Bezel options Faceplates and bezels are available in four styles to suit the host machine please see de...

Page 6: ...de fitting 3 1 2 Note Guide Fitting Removal Refer figure 3 1 2 To remove the note guide first remove the faceplate bezel Push together the two sides of the note guide and pull away from the validator...

Page 7: ...assembly With the exception of MDB the GBA ST2 will be connected to the host machine using a cable assembly terminated with a 20 way connector as denoted in section 8 0 Electrical Connections 4 1 NAMA...

Page 8: ...disable modes a sample note must then be presented for scanning If the operation is successful the validator will return to normal operation mode If it is unsuccessful it will remain in the program mo...

Page 9: ...2 is not a necessity it is recommended periodically for preventative maintenance and also after any change to the software configuration of the unit Equipment Required Calibration Paper Procedure 1 Th...

Page 10: ...or firmware has been changed or following modification to the configuration of the unit via a programming card or GBATalk Tools In general re calibration of the unit should be carried out once every 6...

Page 11: ...ng either the GBATalk PC program or Program Card facility as mentioned above Two kinds of program card are available Firstly a card to set all options all options must be specified and secondly indivi...

Page 12: ...r checks at start up This mode is designed to enable the GBA ST2 to be used in battery applications It is anticipated that the unit is powered up only when a customer wants to present a note e g by li...

Page 13: ...This option can be set from 0 to 255 and determines the time in minutes that the validator is disabled following the detection of the set number of successive OASG rejects If this option is set to ze...

Page 14: ...ecurity incident has been reported GBA ST2 DEFAULT SETTING GUIDELINES Note The GBA ST2 can be configured in many ways allowing the user to customize the unit to their specific requirements The configu...

Page 15: ...r Consumption Quiescent 200mA Validating 800mA Stalled 1 4A Maximum Output Low Voltage 0 4VDC Minimum Output High Voltage 2 4VDC Maximum output sink current 50mA 12VDC Open collector Input pull up to...

Page 16: ...s is required Part Number HCC Please contact Technical Support for details MDB Connection If the validator is used in an MDB interface application an additional power supply or conversion board is req...

Page 17: ...c 9 Whi Blk Grn n c n c n c RXD 10 Blue Inhibit Control Input Enable Inhibit Control Input Enable Inhibit Control Input Enable n c 11 Violet Vend 1 Output Confirm Signal To Start Serial CTS n c n c 1...

Page 18: ...cted selects pulse mode BUSY Output a low output indicates when the acceptor is operating DATA Output used to send data to the host machine CTS Input from host that tells acceptor that host is ready t...

Page 19: ...nlatch and then gently pivot top section backwards to open and remove 4 Using the Cotton swab or cloth dipped in the cleaning solution carefully clean all sensors and plastic windows using light force...

Page 20: ...sonnel when assisting customers over the phone or by email Normal Run Mode The LED will be permanently Green solid on If a note is rejected a flash code is given Green LED Flashed off If the note is r...

Page 21: ...programmed notes are rejected 1 Acceptance inhibited for all notes 2 MASG not working 3 Escrow sensor not working 1 Software configuration 2 Internal MASG 1 Use on board button or GBA Talk to enable...

Page 22: ...GBA Global Bill Acceptors GBA ST2 Operations Manual Page 22 of 25 Astrosys International Ltd January 2009 GBA ST2 Op Manual V1 01 GBA ST2 DIMENSIONS WITH COMPACT BEZEL...

Page 23: ...GBA Global Bill Acceptors GBA ST2 Operations Manual Page 23 of 25 Astrosys International Ltd January 2009 GBA ST2 Op Manual V1 01 GBA ST2 DIMENSIONS WITH STANDARD BEZEL...

Page 24: ...GBA Global Bill Acceptors GBA ST2 Operations Manual Page 24 of 25 Astrosys International Ltd January 2009 GBA ST2 Op Manual V1 01 GBA ST2 DIMENSIONS WITH STANDARD FACEPLATE...

Page 25: ...chnology Park 63 85 Turner Street Wantage Port Melbourne Oxon OX12 9FA Victoria 3207 U K Australia Tel 44 0 1235 772201 Tel 613 9646 6446 Fax 44 0 1235 772202 Fax 613 9646 6447 E Mail sales astrosyste...

Reviews:

Related manuals for ST2