background image

1

Pro

 line

1  

Introduction

Thank you for purchasing the Gavita 

CT

 2000

e

 LED EU 230-400V. This manual describes the mounting and installing of 

the product and also describes how to use the product. Mounting and installation of the Gavita 

CT

 2000

e

 LED EU 230-400V 

luminaire may only be executed by certified service personnel. Please read and understand this manual completely before 
using the product. Only use the product as specified in this manual.

1.1  

Used Symbols

Warning!

 A warning indicates severe damage to the user and/or product may occur when a procedure is not carried 

out as described.

Caution!

 A caution sign indicates problems may occur if a procedure is not carried out as described. It may also 

serve as a reminder to the user.

Note:

 A note gives additional information, e.g. for a procedure.

This symbol indicates that the Gavita can reach very high temperatures (>75 °Celsius). Observe a cool down period 

before performing maintenance.

The symbol on the material, accessories or packaging indicates that this product may not be discarded as 

household waste. By disposing of the equipment in the proper way, you will be helping to prevent possible risks 

to the environment and public health, which might otherwise be caused by improper handling of the discarded 

equipment. Recycling of materials contributes tot the conservation of natural resources. Therefore, please do not 

dispose of your old electronics and electrical appliances via household waste.

1 m

This symbol indicates the minimum distance between the luminaire and the lit surface.

This symbol indicates that the luminaire contains a bright light source. Do not stare into the light source when 

switched on.

This symbol indicates a risk of electric shock. Do not remove the lens. There are no servicable parts inside the 

luminaire.

2  

Product description

The Gavita 

CT

 2000

e

 LED EU 230-400V is an electronic horticultural LED luminaire. The Gavita 

CT

 2000

e

 LED EU 230-400V is 

intended to be used in greenhouses or in climate rooms (indoor or outdoor).
Reinforced insulation was provided between input circuit and output/ dimming circuit. Basic insulation between output 
circuit and dimming circuit
In this manual, the Gavita 

CT

 2000

e

 LED EU 230-400V will be referred to as: “the luminaire”.

Gavita

 

CT

 2000

e

 LED EU 230-400V

Summary of Contents for Proline CT 2000e

Page 1: ...carded as household waste By disposing of the equipment in the proper way you will be helping to prevent possible risks to the environment and public health which might otherwise be caused by improper handling of the discarded equipment Recycling of materials contributes tot the conservation of natural resources Therefore please do not dispose of your old electronics and electrical appliances via ...

Page 2: ...s Version Gavita CT 2000e LED EU 230 400V Product weight 14 kg Dimensions in cm L W H 74 9 x 30 x 10 cm Temperature case 75 C Temperature ambient 0 45 C Degree of protection IP66 Input voltage 230 400 VAC Current Max 4 0 A Input power typical 780 W Power factor 0 95 Total Harmonic Distortion 15 Frequency 50 60 Hz Certification CE UKCA CB Insulation Class I requires an earth connection Power inlet ...

Page 3: ...taring into the luminaire at a distance closer than 6 5 m is not expected This product may cause interference to radio equipment and should not be installed near maritime safety communications equipment or other critical navigation or communication equipment operating between 0 45 30 MHz Do not use the luminaire when either its optics LED boards or its power cord are damaged Replace the power cord...

Page 4: ... and installing of the luminaire may only be executed by certified service personnel in accordance with the applicable local laws and regulations 6 Warning The fitter is responsible for correct and safe installation 6 Warning Ensure the local cabling can support the voltage and current requirements of the luminaire 6 Warning Avoid coiled cords Coiled cords may lead to electromagnetic interference ...

Page 5: ...ains the following items A 2 x EMC ferrite snap on black bag 13x12x5x25 5x2 4 B 4 x Gavita splitter 1 to 2 6P6C grey RJ25 in bag C 8 x grey modular jack interconnect cable 6P6C RJ25 in bag D 8 x SNAP ON ferrite core grey in bag 7 4 Preparation for use with a controller Using a daisy chain setup a maximum of 100 luminaires can be connected to one controller Up to 500 luminaires per daisy chain can ...

Page 6: ...end in place with a cable gland 12 4 Remove the dummy from the input port on the second luminaire 5 Use a grey 6P6C modular jack interconnect cable item C with integrated ferrite cores to connect the output port of the first luminaire to the input port of the second luminaire 13B The indicator light will blink when the connection is successful 6 Use a grey 6P6C modular jack interconnect cable item...

Page 7: ...d 14D 5 Repeat these steps to connect up to 100 luminaires per splitter output port 14E Up to 500 luminaires can be connected to the primary channel 6 Snap on two grey ferrite cores item D on the grey interconnect cable item C close to the 6P6C plugs 7 Use the grey 6PC6 modular jack interconnect cables item C to connect the outport of a splitter to the inport of the next 14B 8 Use the black second...

Page 8: ...ld timers to switch the luminaire 1 Switch off mains power 2 Connect the power cable to the mains The Gavita CT 2000e LED 240 400 V power cables connect to either a 240V receptacle or an open end cable Use the correct cable and connector for your application 15 Cable description Gavita CT 2000e LED 240 400 V Wire 240V 400V Blue Neutral N Phase L Brown Phase L Phase L Green Ground Ground 3 Plug the...

Page 9: ...land RST20i3 male connection inwards and pull the Wieland RST20i3 female connection from the luminaire 16 B 1 B 2 16 10 Storage and disposal Store the luminaire in a dry and clean environment with an ambient temperature of 20 85 Celsius The product must not be discarded as unsorted municipal waste but must be collected separately for the purpose of treatment recovery and environmentally sound disp...

Page 10: ...g 8 1437 EL Rozenburg NH The Netherlands T 31 0 297 380 450 F 31 0 297 380 451 info gavita com www gavita com Manual Gavita Pro CT2000e 230 400V Changes reserved Version v21 47 Not for sales or use in the Netherlands Pro line Pro line ...