Precautions when using the luminaire

 

6

Warning!

 Always wait 20 - 30 minutes for the luminaire to cool down!

9  

Inspection, maintenance and repair

 

6

Warning! 

Disconnect the luminaire from mains before performing any maintenance or repairs.

 

6

Warning!

 Do not connect or disconnect the Wieland RST20i3 plug under load.

 

6

Warning!

 Do not open or disassemble the luminaire, it contains no servicable parts inside. Opening the luminaire can 

be dangerous and will void the warranty.

 

6

Warning!

 Always allow for a cool down period of at least 30 minutes before touching the luminaire.

 

1

Caution!

 Do not clean the luminaire with detergents, abrasives or other agressive substances.

• 

Regularly check the luminaire for dust or dirt buildup. Clean if necessary. Contamination may couse overheating and 
decreased performance. Clean the electronic ballast and the outside of the luminaire using a dry or damp cloth.

• 

Regularly check the cables of the luminaire to ensure it is undamaged.

• 

Regularly check the wiring of the product to ensure it is undamaged.

9.1  

Disconnecting the luminaire from the mains

 

6

Warning!

 Do not connect or disconnect the Wieland RST20i3 plug under 

load.

1.  Switch off mains power.
2.  Press the pin on the Wieland RST20i3 male connection inwards and pull 

the Wieland RST20i3 female connection from the luminaire (16).

B1

B2

16 

10  

Storage and disposal

• 

Store the luminaire in a dry and clean environment, with an ambient temperature of -20 ~ 85 °Celsius.

• 

The product must not be discarded as unsorted municipal waste, but must be collected separately for the purpose of 
treatment, recovery and environmentally sound disposal.

11  

Warranty

Gavita International b.v. warrants the mechanical and electronic components of their product to be free of defects in 
material and workmanship if used under normal operating conditions for a period of five (5) years from the original date 
of purchase. If the product shows any defects within this period and that defect is not due to user error or improper use 
Gavita International b.v. shall, at its discretion, either replace or repair the product using suitable new or reconditioned 
products or parts. In case Gavita International b.v. decides to replace the entire product, this limited warranty shall apply 
to the replacement product for the remaining initial warranty period, i.e. five (5) years from the date of purchase of the 
original product. For service return the Gavita CT 2000e LED EU luminaire to your shop with the original sales receipt.

 

2

Please note:

 Greater than 15% of the diodes must be non-functional before the unite can be considered defective.

See gavita.com/warranty for more information.

Summary of Contents for Proline CT 2000e

Page 1: ...carded as household waste By disposing of the equipment in the proper way you will be helping to prevent possible risks to the environment and public health which might otherwise be caused by improper handling of the discarded equipment Recycling of materials contributes tot the conservation of natural resources Therefore please do not dispose of your old electronics and electrical appliances via ...

Page 2: ...s Version Gavita CT 2000e LED EU 230 400V Product weight 14 kg Dimensions in cm L W H 74 9 x 30 x 10 cm Temperature case 75 C Temperature ambient 0 45 C Degree of protection IP66 Input voltage 230 400 VAC Current Max 4 0 A Input power typical 780 W Power factor 0 95 Total Harmonic Distortion 15 Frequency 50 60 Hz Certification CE UKCA CB Insulation Class I requires an earth connection Power inlet ...

Page 3: ...taring into the luminaire at a distance closer than 6 5 m is not expected This product may cause interference to radio equipment and should not be installed near maritime safety communications equipment or other critical navigation or communication equipment operating between 0 45 30 MHz Do not use the luminaire when either its optics LED boards or its power cord are damaged Replace the power cord...

Page 4: ... and installing of the luminaire may only be executed by certified service personnel in accordance with the applicable local laws and regulations 6 Warning The fitter is responsible for correct and safe installation 6 Warning Ensure the local cabling can support the voltage and current requirements of the luminaire 6 Warning Avoid coiled cords Coiled cords may lead to electromagnetic interference ...

Page 5: ...ains the following items A 2 x EMC ferrite snap on black bag 13x12x5x25 5x2 4 B 4 x Gavita splitter 1 to 2 6P6C grey RJ25 in bag C 8 x grey modular jack interconnect cable 6P6C RJ25 in bag D 8 x SNAP ON ferrite core grey in bag 7 4 Preparation for use with a controller Using a daisy chain setup a maximum of 100 luminaires can be connected to one controller Up to 500 luminaires per daisy chain can ...

Page 6: ...end in place with a cable gland 12 4 Remove the dummy from the input port on the second luminaire 5 Use a grey 6P6C modular jack interconnect cable item C with integrated ferrite cores to connect the output port of the first luminaire to the input port of the second luminaire 13B The indicator light will blink when the connection is successful 6 Use a grey 6P6C modular jack interconnect cable item...

Page 7: ...d 14D 5 Repeat these steps to connect up to 100 luminaires per splitter output port 14E Up to 500 luminaires can be connected to the primary channel 6 Snap on two grey ferrite cores item D on the grey interconnect cable item C close to the 6P6C plugs 7 Use the grey 6PC6 modular jack interconnect cables item C to connect the outport of a splitter to the inport of the next 14B 8 Use the black second...

Page 8: ...ld timers to switch the luminaire 1 Switch off mains power 2 Connect the power cable to the mains The Gavita CT 2000e LED 240 400 V power cables connect to either a 240V receptacle or an open end cable Use the correct cable and connector for your application 15 Cable description Gavita CT 2000e LED 240 400 V Wire 240V 400V Blue Neutral N Phase L Brown Phase L Phase L Green Ground Ground 3 Plug the...

Page 9: ...land RST20i3 male connection inwards and pull the Wieland RST20i3 female connection from the luminaire 16 B 1 B 2 16 10 Storage and disposal Store the luminaire in a dry and clean environment with an ambient temperature of 20 85 Celsius The product must not be discarded as unsorted municipal waste but must be collected separately for the purpose of treatment recovery and environmentally sound disp...

Page 10: ...g 8 1437 EL Rozenburg NH The Netherlands T 31 0 297 380 450 F 31 0 297 380 451 info gavita com www gavita com Manual Gavita Pro CT2000e 230 400V Changes reserved Version v21 47 Not for sales or use in the Netherlands Pro line Pro line ...

Reviews: