7
7.6
Connecting up to 500 or 1,000 LED fixtures
Using a setup with daisy-chained splitters, up to 500 LED fixtures on EL1 and 1,000 LED fixtures on EL2 (over two channels)
can be connected as shown in fig.12.
•
Use the controller cable (RJ45-RJ9) to connect the primary channel of the controller to the input port of the first splitter (fig.
12A).
•
Remove the dummy from the input port of the LED adapter (fig. 10).
Note: Keep the dummy in a safe place! The dummy is necessary to operate the LED fixture in stand-alone mode.
•
Use a RJ45-RJ45 modular jack interconnect cable (item C) to connect the output port of the splitter to the input port of
the first LED fixture adapter (fig. 12C).
•
Use a RJ45-RJ45 modular jack interconnect cable (item C) to connect the output port of the first LED adapter to the input
port of the second (fig. 12D).
•
Repeat these steps to connect up to 100 LED fixtures per splitter output port (fig. 12E). Up to 500 LED fixtures can be
connected to the primary channel.
•
Use RJ45-RJ45 modular jack interconnect cables (item C) to connect the outport of a splitter to the input port of the next
(fig. 12F).
•
Use the secondary channel (fig.12G) to connect another 500 LED fixtures, in the same way the LED fixtures are connected to
the primary channel.
Warning! Ensure the power cord and the controller cables do not touch the LED fixture.
Avertissement! Assurez-vous que le cordon d'alimentation et les câbles de contrôle ne touchent pas le dispositif à DEL.
Warning! Distribute number of LED fixtures evenly over daisy chains.
Avertissement! Distribuez uniformément le nombre de dispositifs à DEL sur les chaînettes en sangle.
Warning! Ensure the repeater bus connections are properly integrated within a correct installation for best results
Avertissement! Assurez-vous que les raccordements de barres omnibus répéteurs sont adéquatement intégrés dans les
limites d'une bonne installation pour obtenir les meilleurs résultats.
Warning! Boosters should never be used to expand
Avertissement! Ne jamais utiliser d'éclairages horticoles de croissance et de floraison pour étendre.
Warning! The maximum cable length per splitter is 250 m (100 interconnect cables).
Avertissement! La longueur maximale de câblage par séparateur est de 250 m (100 câbles de liaison).