background image

EN

13

14

CONNECTING HEADPHONES

The MDLink wireless audio system 

allows you to choose one of 4 

channel options. 

1   Plug your headphones into a 6.35 mm 

headphone jack on the MDLink module. 

2   Turn on the detector and the module 

(sequence doesn't matter).

3   Quick press          to step through the 

channel selection.

4   Activate the transmitter (TRANS) in the 

Settings Menu by setting it to the same 

channel as the module. Once the 

detector and the module are 

successfully paired, you will hear a beep 

sound and the LED light will flash 

constantly.

5   Use the          /          buttons on the 

module to adjust the volume to your 

preferred level.

6   Attach the module to a breast pocket or 

a belt.

If two MDLink wireless audio 
systems are located close to each 

other, they need to operate on different 
channels to eliminate mutual 
interference. If the transmitter is 
disconnected from the module (due to 
the channel change or connection loss), 
you will hear a disconnect signal while 
the current channel LED indicator will 
blink in a repeating pattern.

Module Charging / Low Battery Warning

How to connect your headphones to the MDLink module:

The MDLink module contains a rechargeable Li-Ion 

battery and a built-in charge controller.

To charge the battery, you need to plug one end of the 

USB/mini USB cable (supplied) into the mini-USB output 

on the module and the other end into the USB power 

adapter (supplied) or a power bank (not supplied).

While being charg

ed, the LED light will flash blue. Once 

charging is complete, the LED will turn off by itself.

When the module is turned on, the channel LEDs will 

flash briefly. Depending on the number of LED lights, you 

can get a rough estimate of the battery charge level (each 

LED represents 25%):

• One Light = 25%
• Two Lights = 50%
• Three Lights = 75%
• Four Lights = 100%

When battery level drops to roughly 5%, the battery 

LED on the module will start blinking red and you will 

hear a warning beep in your headphones.

When battery level approaches roughly 2%, the LED 

indicator  on  the  module  will  be  flashing  red  constantly 

and the beep will sound every 30 seconds until the 

battery is fully discharged.

There are 10 levels of volume control. 

Once the maximum or minimum volume 

is reached, you will hear a low pitch 

sound indicating the upper or lower 

volume limit.

After  turning  off  the  MDLink  power 

button, the current channel and volume 

level will remain in the module’s memory.

Volume 

Control

Channel Switch

Power 

Button

Battery 

Status LED

Channel 

Indicator LED

6.35 mm (1/4’’)

Headphone

Socket

Charging

Socket

Summary of Contents for MIL MD

Page 1: ...OPERATING MANUAL Gauss MD PROFESSIONAL METAL DETECTOR with Gauss MiL rmware...

Page 2: ...tenance Safety 17 Error Messages 18 Technical Specifications TABLE OF CONTENTS 3 4 5 5 6 7 9 11 12 12 12 13 14 15 15 16 16 17 THE USE OF THE METAL DETECTOR WHILE CONDUCTING MINE CLEARANCE ACTIVITIES i...

Page 3: ...l attachment bolt 2 pcs 10 Tiger search coil coil cover connector protection cap 11 Tiger search coil coil cover connector protection cap 12 MarsMD Pointer 13 Carry bag 1 The Gauss MiL can be addition...

Page 4: ...oosening direction Tightening direction Coil attachment bolt Rubber washers 4 Wrap the coil cable around the lower shaft in such a manner that the first loop close to the coil goes over the top of the...

Page 5: ...gs and modes features will allow you to use your metal detector in the most effective and efficient way possible while searching 1 Assemble the device according to the instructions given on page 4 see...

Page 6: ...target depending on its characteristics Displays the value of the GAIN setting which stands for the detector sensitivity Battery Status Indicator Indicates the current charge level of the battery Sta...

Page 7: ...atest settings changes are saved in non volatile memory of the device before it turns o FREQUENCY FREQ LF1 LF5 is the detector s operating frequency with the value within the 16 kHz 200 Hz range The L...

Page 8: ...rian and military demining iL is a special mode designed to detect metal containing explosives In this mode the metal detector has one tone audio indication without determining the type of metal ferro...

Page 9: ...do the opposite action decrease the value using Press the buttons several more times until you get such GEB value when the sounds become as quiet as possible or completely silent while the coil is swu...

Page 10: ...lue provides the current information about the ground you are searching on The range of 6 20 is common to poorly mineralized sandy soils The range of 20 45 is typical for dry clay loams and black soil...

Page 11: ...target which additionally helps to identify its position and estimate the burial depth To determine the exact position of a target 1 After the approximate target location is detected move the coil aw...

Page 12: ...N MODE Target ID is the number produced by the device while identifying a buried object based on the electromagnetic properties of metals and physical dimensions of the item found Ferrous targets most...

Page 13: ...wer adapter or other device the charging cable is plugged into Important To avoid battery damage never charge a battery in an area with an ambient temperature of less than 5 C Always allow the control...

Page 14: ...Li Ion battery and a built in charge controller To charge the battery you need to plug one end of the USB mini USB cable supplied into the mini USB output on the module and the other end into the USB...

Page 15: ...the contacts are clean 2 Ensure the nut on the coil connector is firmly tightened 3 Move away from the source of interference 4 Try switching to another operating frequency 5 Reduce the detector s se...

Page 16: ...treated with due care Use a screen protector to keep it pristine Do not expose the detector to extreme temperatures Operating temperature range 20 C to 45 C GENERAL CARE Do not use solvents to clean...

Page 17: ...tness levels internal Li ion battery up to 24 hours but not less than 15 hours Detecting Range Operating Frequency Indication Ground Balance Built in Transmitter LCD Backlight Power Supply Operating T...

Page 18: ...gaussmil com ___________________ E mail mail marsmd com...

Reviews: