5.10 Anti-freeze Protection( Optional):
Under the state of shutdown:
1. When the temperature that detected by the inner sensor ≤5
℃
, the function of anti-freeze protection will
be turned on, and forced to turn on the heating device, anti-freeze protection icon displayed.
2. When the temperature that detected by the inner sensor
>
8
℃
, the function of anti-freeze protection
will be turned off and return to normal working, anti-freeze icon disappeared.
VI
Shortcut Menu Settings
Under the state of shutdown, long press S1+S5 buttons to enter into the parameters setting interface of Secret
Menu, input the password 5138 by S4 or S5 button, then press S3 to confirm the switchover and enter into the
Menu Parameters Setting interface.
The following table is the detailed information of the parameters:
Parameters
No.
Meaning of the
Parameters
Default Value
Setting Range
Notes
P00
Factory Reset
Displayed 53
,
Password 55
00—99
Changed it to 55 and press S3 to
restore factory defaults.
P01
Set the upper
temperature limit
37
℃(
98
℉)
00—99.5
℃
(
32-211
℉)
When finished the setting,be
sure that the upper limit > lower
limit
P02
Set the lower
temperature limit
5
℃(
41
℉)
00—99.5
℃
(
32-211
℉)
When finished the setting,be
sure that the upper limit > lower
limit
P03
Reserved
99.5
℃
00-99
℃
Reserved
P04
Reserved
00
℃
00—99
℃
Reserved
P05
Temperature backlash
is ON.
1.5
℃(
3
℉)
0—10
℃(
0-20
℉)
P06
Temperature backlash
is OFF.
0
℃
0—10
℃(
0-20
℉)
P07
ON/OFF of anti-freeze
protection function
OF
ON—OF
=ON means anti-freeze
protection function is ON
,
=OF
means anti-freeze protection
function is OFF.
P08
Temperature value
when the anti-freeze
protection is ON
5
℃(
41
℉)
0—10
℃(
32-50
℉)
P09
Temperature value
when the anti-freeze
protection is OFF
8
℃(
46
℉)
0—10
℃(
32-50
℉)
P10
Temperature of High
55
℃(
131
℉)
0--99
℃(
32-211
℉)
=0 means High Temperature