User Manual
2
Function of the Buttons
S1
: Local time/Time-periods parameter setting
/Confirmation key
S2
: Vacation mode /Temperature Unit switchover /Back
shortcut key
S3
: ON/OFF/Mode switchover/Toggle key
S4
: Parameter up button/Current
temperature setting key
S5
: Parameter down button/Current
temperature setting key
V Operation Instruction
5.1 ON/OFF Settings
After the device finish wiring and power on, enter the off state by default, display the word OFF, and all outputs are
forced off. Short press S3 button to enter into the ON/OFF settings. When turned the device on, it will display the
current week, local time, working mode, current temperature, output status and other information,
5.2 Switch the Temperature Unit (
℃
/
℉
)
In the normal working interface, long press S2 button to switch the temperature unit between
℃
and
℉
.
5.3 Chang the Setting Temperature
In the normal working state, press S4 or S5 button to enter into the temperature setting interface , the setting range
is 5-37
℃
。
The values could be adjusted by S4 or S5 button, press S3 button or delay 8 seconds without key
operation will automatically return to normal working interface.
Under manual mode
,
when adjust the temperature according to the steps above, the setting temperature will be
saved until next change.
Under vacation mode
,
when adjust the temperature according to the steps above, the setting temperature will be
saved until this mode is off.
5.4 Control Instruction
GM7-EH
:
1. When the indoor temperature < setting temperature -1.5
℃
, the device is on and display the output
icon.
2. When the indoor temperature ≥ setting temperature, the device is off and the output icon disappears.
5.5 Manual/Auto Mode Settings
Press S3 button to select between manual mode and auto mode
,
choose the desired mode then delay for 3s
it will confirmed automatically.