background image

SUSIE® S1001

Prehospital and Nursing Care

User Guide

User Guide 1

9

.

9

.1

© Gaumard Scientific Company, 201

All Rights Reserved

www.Gaumard.com

SUSIE

®

  S1001  is  an  interactive  educational  system 

developed to assist a certified instructor. It is not a substitute 

for  a  comprehensive  understanding  of  the  subject  matter 

and not intended for clinical decision making.

Summary of Contents for SUSIE S1001

Page 1: ...Scientific Company 2019 All Rights Reserved www Gaumard com SUSIE S1001 is an interactive educational system developed to assist a certified instructor It is not a substitute for a comprehensive unde...

Page 2: ......

Page 3: ...Procedures 2 Cleaning 3 Stoma and Breast Examination Insert Guidelines Warnings and Maintenance 3 Electrical Therapy Warnings 4 2 1 Features 5 Airway 5 Spontaneous Breathing 5 Cardiac 5 Circulation 5...

Page 4: ...20 Intravenous Extremities 22 4 4 Systemic 25 Interchangeable Breast Examination Package 25 Breast Pathology 25 Bowel Sounds 25 Colostomy and Ileostomy 26 Nasogastric Feeding 26 Intestinal Access 28...

Page 5: ...ging Vital Signs 44 Applying Changes 45 Creating Palette Items 46 5 4 Streaming Audio 48 6 Appendix 49 6 1 Troubleshooting 49 Miscellaneous Issues 49 6 2 Scenarios 50 6 3 More about Scenarios 51 Think...

Page 6: ...hip Electronic transmission is warranted to be free from defects at the moment of transmission Your sole and exclusive remedy and Gaumard s sole liability is to replace the defective media or to repea...

Page 7: ...al Ball point pens ink and markers permanently stain the skin Do not wrap this or any other Gaumard product in newsprint Marks made with ballpoint pens ink or marker cannot be removed Replacement part...

Page 8: ...tems please contact customer service WARNING Vein tubing contains latex which may cause allergic reactions Users allergic or sensitive to latex should avoid contact Discontinue use of this product and...

Page 9: ...clean hands Always palpate the breast using the fatty pads of the middle three fingers Prevent items from resting or pressing against the stomas breasts as indentations will form on the pressure point...

Page 10: ...arcing Make sure the simulator is not in contact with any electrically conductive surfaces Use the simulator only in a well ventilated area free of all flammable gases NEVER attempt to service or modi...

Page 11: ...ble breathing patterns Accommodates assisted ventilation including bag valve mask and mechanical support with chest rise Cardiac Multiple heart sounds Chest compressions are measured and logged Electr...

Page 12: ...eft breast includes six discreet nodes representing in a slightly exaggerated form various stages of fibrocystic disease chronic mastitis Normal right breast free of lumps Options OMNI 2 ready Finger...

Page 13: ...simulator on a patient table capable of supporting the weight of a real adult patient WARNING To avoid damage to the simulator please store and ship it in the clear poly bag provided Leg Assembly Fol...

Page 14: ...case The package includes 1 normal right breast labeled R1 and 1 abnormal left breast labeled L1 For detailed information on pathology of each breast go to page 32 WARNING Always store the breast inse...

Page 15: ...eft side of the chest cavity Damage to this connection will require repair not covered under warranty 4 Carefully place the breast inserts beneath the chest skin 5 Secure the chest skin by first attac...

Page 16: ...battery lead as part of the first install process 1 Locate the white connectors on Susie s right side 2 Connect the internal battery leads by clipping the white connectors together 3 Unscrew the wais...

Page 17: ...indicator refer to Working with UNI section WARNING Do not store the simulator with a discharged battery It is good practice to re charge the battery at the end of every simulation session In additio...

Page 18: ...SUSIE S1001 User Guide 12 Using SUSIE S1001 2 Double click on the UNI icon 3 Select Susie S1001 and click START Susie S1001 will establish communication within 1 minute...

Page 19: ...tubes The airway has anatomical landmarks and can be intubated orally or nasally If the endotracheal tube is inserted too deep the left lung is automatically disabled realistically demonstrating righ...

Page 20: ...mmended Device Size Intubation Blade size Miller 4 or MAC 3 5 LMA Size 4 Nasal Intubation 8 Fr catheter Oral Intubation ETT 7 0 or 7 5 Airway Complication Use the software controls to enable the airwa...

Page 21: ...hea to be pierced during a simulation with a real device to observe chest rise Lubricate the tracheostomy tube before inserting To replace the tracheostomy tape that has be punctured follow the steps...

Page 22: ...ttern and inspiration percentage using the software controls The breathing patterns are synchronized with the lung sounds and chest rise Lung Sounds Left and right lung sounds are available normal whe...

Page 23: ...WARNING Do not perform mouth to mouth ventilation Doing so may lead to molding of the airway The airway itself cannot be sanitized or cleaned 4 3 Circulation Heart Sounds SUSIE S1001 is equipped with...

Page 24: ...reen Doing so will not create a fire hazard nor is there risk of shock to the provider but internal damage to the simulator will result This type of damage is considered improper use and it is NOT cov...

Page 25: ...es SUSIE detects when a shock has been delivered Select whether to convert the current rhythm to a normal sinus rhythm ECG Snap Option Purchase the ECG Snap chest skin that connects directly to the EC...

Page 26: ...e severe hypotension Proper chest compressions result in palpable carotid pulses The simulator s pulses are dependent on blood pressure heart rate and rhythm Programmable Blood Pressure Programmable b...

Page 27: ...the BP cuff before measuring blood pressure Blood Pressure Calibration Before starting the calibration process place the blood pressure cuff on the simulator as it would be placed as instructed above...

Page 28: ...ntervals 9 At the end of the calibration click SAVE to accept and close the calibration wizard Intravenous Extremities SUSIE S1001 is equipped with bilateral IV training arms that can be used for bolu...

Page 29: ...h tubing and the drain tube with pinch clamp 2 Connect the drainage hose to the IV arm Leave the drain clamp open 3 Fill the syringe with fluid 4 Connect the filling hose to the other port 5 Push flui...

Page 30: ...will seal and the veins will remain collapsed Cleaning the Vasculature Clean and dry the forearm vasculature at the end of the simulation ses sion to prevent mold or clogs To clean and dry the IV arm...

Page 31: ...rmal Left Breast Six discreet nodes on one side and a somewhat larger node on the other side of the breast This breast represents in a slightly exaggerated form various stages of fibrocystic disease c...

Page 32: ...y separate the stoma flange from the torso and do not apply force directly to the stoma tissue itself For care and caution information refer to the Care and Maintenance section Review the section Clea...

Page 33: ...efore the software logs the tube placement will void the warranty and can permanently damage the simulator Draining the Gastric Fluids 1 Turn the simulator ON 2 Locate the stomach intestine fluid acce...

Page 34: ...ing with a reservoir for administering enemas and removing intestinal fluids introduced by way of nasogastric feeding Cleaning the Internal Reservoirs To properly clean the internal stomas and stomach...

Page 35: ...ents of the reservoir 7 Replace the reservoir in the abdominal cavity 8 Secure the abdominal cover back in place OB GYN Examination Package SUSIE S1001 includes a gynecologic package that allows the p...

Page 36: ...cludes the following items Item QTY Anteverted Uterus 1 Retroverted Uterus 1 IUD Uterus Installed 1 6 8 Week Pregnant Uterus 1 10 12 Week Pregnant Uterus 1 20 Week Pregnant Uterus 1 6 8 Week Pregnant...

Page 37: ...To interchange the uterus and or the cervix insert 1 Gently lift the abdominal skin cover 2 Unhook the round ligaments from both sides of the uterus 3 Gently twist the uterus counter clockwise to unf...

Page 38: ...4 white connectors 6 Insert the uterus and gently twist clock wise 7 Hook the round ligaments to the torso 8 Velcro the lower torso skin back in place Urinary Catheterization SUSIE features an intern...

Page 39: ...the male genitalia 1 Remove the female catheter adapter Set the female catheter adapter aside and save for female catheterization procedures 2 Insert the male genitalia urethra tube into the catheter...

Page 40: ...or male genitalia Install the female genitalia adapter to prevent leaks around the catheter when performing a female catheterization WARNING Remove all fluids after each use Draining the Bladder 1 Dr...

Page 41: ...M sites are located on both deltoids and quadriceps for placement and technique exercises WARNING Do not inject fluids into the intramuscular sites Oxygen Saturation Monitor Placement Detection The si...

Page 42: ...ening on the fingertip The feature allows participants to practice finger stick technique and collect simulated blood samples WARNING Use only Gaumard s provided simulated blood to fill the internal r...

Page 43: ...S1001 37 2 Locate the black port on the simulator s left arm 3 Connect the finger stick fill syringe to the black port 4 Inject up to 2 cc s of simulated blood or fluid 5 Remove the fill syringe 6 Ena...

Page 44: ...terus with large ovarian cyst Uterus with medium ovarian cyst Enlarged uterus Small uterus Bicornuate uterus Uteri with Internal Palpable Abnormal Pathologies This optional package includes Normal ute...

Page 45: ...the status of the radio link between the tablet s USB RF module and the simulator Full bars indicate excellent communication i e normal operation Back Up Battery Indicator The battery status indicator...

Page 46: ...the sim ulator to stand by mode and then again to resume 5 2 Quick Launch The UNI interface opens up showing the quick launch page for the scenarios This page is used to easily access the preprogramme...

Page 47: ...es can be selected at the same time and the list of scenarios on the right will display only the scenarios included in the selected categories Selecting the Scenario Click on one of the scenarios list...

Page 48: ...ds the appropriate scenario and starts it automatically Favorites The Favorites feature allows users to reduce the number of scenarios highlighted to those within the categories that will be used most...

Page 49: ...the simulator s vital signs The individual parameter controls displayed on the details tab provide the simplest method for controlling the simula tor s vital signs sounds and features The Status Detai...

Page 50: ...ntrol e g heart rate blood pressure respiratory rate etc Alternatively use the keyboard for manual entry and click the green checkmark to confirm the change To change patterns sounds and rhythms click...

Page 51: ...e simulator s condition until the new settings are submit ted using the Apply panel After the list of changes is created click NOW to update the vital signs instantly Alternatively click a trending ti...

Page 52: ...ital sign settings into a single loadable object Use a palette item to update a set of vital signs quickly To create a new palette item set the values for the desired vital signs parameters using the...

Page 53: ...SUSIE S1001 User Guide Working with UNI 47 Select the palette item from the Load Palette Item menu and click Load Click the apply option to submit the changes...

Page 54: ...isten to the participant s reply Connect the headset to the PC In UNI locate the streaming icons in the lower right of the screen Select the microphone icon to talk as the simulator s voice Select the...

Page 55: ...at the power supply is connected to the simulator Miscellaneous Issues Compression are not detected Turn Respiratory Rate to zero Follow the calibration procedure Ventilations are not detected Follow...

Page 56: ...en unable to cut down on her drinking She has a PMH of alcoholism for the past 20 years and associated complications including gastritis alcoholic hepatitis and aspiration pneumo nia Mrs Gonzalez take...

Page 57: ...ssessment of a client with spinal cord injury resulting in paralysis Perform complete pain assessment and reassessment Administer medication according to physician orders via multi med line Evaluate r...

Page 58: ...the factory presets The following four guidelines will refine your ability to build the best possible scenarios 1 How will the scenario begin The first thing to consider is the initial condition of th...

Page 59: ...s in the scenario They think that they will remember the learning objectives patient history and other details at the time they are ready to conduct the simulation They usually do not especially when...

Page 60: ...must be triggered by a vigilant facilitator Though it is slower and requires more attention the benefit of Prompt over other modes is that the simulation can be allowed to go in any direction and it w...

Page 61: ...Router to USB pow er supply Computer can be packaged with router con nected 3 Or connect the TPLink to the wall outlet 4 Open the Wireless Network Connection on the Monitor Computer and connect to the...

Page 62: ...k Connect manually 2 Start the UNI control software on the control computer 3 On the UNI menu bar click the Gear Monitors Configuration 4 The simulator Virtual Mon itor Setup window is dis played now...

Page 63: ...SUSIE S1001 User Guide Wireless Network 57 12 Click Connect to accept the incoming connection...

Page 64: ...quent purchasers or users of the product acquire the product as is and this limited warranty does not apply This limited warranty applies only to the products manufactured and produced by Gaumard This...

Page 65: ...cess to the simulator for possible troubleshooting as needed Technical Support Email support gaumard com USA 800 882 6655 INT 01 305 971 3790 9 2 General Information Sales and Customer Service E mail...

Page 66: ...e Seatbelt Susie Krash Kids Premie UNI Omni Omni 2 SmartSkin are trademarks of Gaumard Scientific Company Always dispose of this product and its components in compliance with local laws and regulation...