200
www.gateway.com
Chapter 7: Troubleshooting
Additional beep codes provided by Intel Management
Modules
In addition to the beep codes above, the following additional beep codes are provided by
the Intel Management Module:
4
Recovery complete
FFh
BIOS recovery succeeded, ready
for power-down and reboot.
Beep Codes
Description
1
Control panel CMOS clear has been initiated
1-5-1-1
Processor failure. Reseat or replace the failed processor.
1-5-2-1
No processor is installed or the CPU 1 socket is empty. Reseat or
replace the failed processor.
1-5-2-2
No processors
1-5-2-3
Processor configuration error or CPU 1 socket is empty. Reseat or
replace the failed processor. In a two-processor system, make sure
the processors are identical.
1-5-2-4
Front-side bus select configuration error.
1-5-4-2
DC power unexpectedly lost.
Beeps
Error Message
POST Progress Code
Description
8510702.book Page 200 Thursday, July 7, 2005 11:21 AM
Summary of Contents for 9715
Page 249: ...244 www gateway com Appendix B 8510702 book Page 244 Thursday July 7 2005 11 21 AM ...
Page 259: ...254 www gateway com Appendix D 8510702 book Page 254 Thursday July 7 2005 11 21 AM ...
Page 277: ...272 www gateway com 8510702 book Page 272 Thursday July 7 2005 11 21 AM ...
Page 278: ...MAN 9715 SRV USR GDE R0 06 05 ...