ISSUED: 04-21-03 SHEET #: 055-9158-1
5 of 8
Visit the Peerless Web Site at www.peerlessindustries.com
For customer service call 1-800-729-0307 or 708-865-8870.
Screw ball and socket assembly (A) into ceiling plate (G). Align the
notch with one of the four holes of the ceiling plate (G) and secure
ball and socket assembly (A) with a M5 x 10 mm socket pin
screw (C) using security allen wrench (B) as shown in detail 1.
Skip to step 6.
DETAIL 1
A
G
A
C
WOOD
JOIST
CEILING
NOTCH
G
Flush Mount Application
SLOT
SLOT
A
ACC 810
1/2 -13 THREADED ROD
Screw ACC 810 into extension column
connector (I). Align slot in ACC 810 with one of
the top holes in extension column connector (I).
Insert and tighten one 10-32 x
3
/
8
socket pin
screw (J) through extension column connector
(I) into slot on ACC 810 using 4 mm security
allen wrench (B). See detail 2.
Align slot in ball and socket mount (A) to one of
the bottom holes in extension column connector
(I). Insert and tighten one 10-32 x
3
/
8
socket pin
screw (J) through extension column connector
(I) into slot in ball and socket mount (A).
See detail 3.
Skip to step 6.
SLOT
DETAIL 2
ACC 810
THREADED
ROD
ACC 810
THREADED
ROD
DETAIL 3
A
I
I
I
J
J
Installation to
Threaded Rod
Accessory ACC 810, threaded rod adapter, is
required. (Sold Separately)
SLOT
B