Table 3-1. SCB Address Switch Settings – PT-353 SW4 and PR-353 SW5
Module
Address
Switch Settings
SW2, Positions
1 2 3 4 5 6
Module
Address
Switch Settings
SW2, Positions
1 2 3 4 5 6
1
0 0 0 0 0 1
19
0 1 0 0 1 1
2
0 0 0 0 1 0
20
0 1 0 1 0 0
3
0 0 0 0 1 1
21
0 1 0 1 0 1
4
0 0 0 1 0 0
22
0 1 0 1 1 0
5
0 0 0 1 0 1
23
0 1 0 1 1 1
6
0 0 0 1 1 0
24
0 1 1 0 0 0
7
0 0 0 1 1 1
25
0 1 1 0 0 1
8
0 0 1 0 0 0
26
0 1 1 0 1 0
9
0 0 1 0 0 1
27
0 1 1 0 1 1
10
0 0 1 0 1 0
28
0 1 1 1 0 0
11
0 0 1 0 1 1
29
0 1 1 1 0 1
12
0 0 1 1 0 0
30
0 1 1 1 1 0
13
0 0 1 1 0 1
31
0 1 1 1 1 1
14
0 0 1 1 1 0
32
1 0 0 0 0 0
15
0 0 1 1 1 1
33
1 0 0 0 0 1
16
0 1 0 0 0 0
34
1 0 0 0 1 0
17
0 1 0 0 0 1
35
1 0 0 0 1 1
18
0 1 0 0 1 0
36
1 0 0 1 0 0
3.3.2
Configuration Switch Banks (PT-353 SW6 and PR-353 SW2)
The Configuration switch bank SW6 on the PT-353 module is located directly behind the GAIN switch
(SW1). Like the Configuration switch bank SW2 on the PR-353 module, this switch bank allows local
configuration of the module. In each position, DOWN enables the function. Table 3-2 gives a numerical
listing of the configuration switch settings for the transmitter.
Summary of Contents for PT-353
Page 2: ......
Page 10: ...No header here 1 2 GatesAir Intraplex Products This page is left blank intentionally...
Page 30: ...No header here 3 16 GatesAir Intraplex Products This page is left blank intentionally...
Page 46: ...No header here 5 4 GatesAir Intraplex Products This page is left blank intentionally...
Page 50: ...No header here 6 4 GatesAir Intraplex Products This page is left blank intentionally...