PT/PR-353 Module Installation & Operation Manual
4 – Remote Configuration & Operation
Version 1.1
4-8
GatesAir
Intraplex Products
Table 4-2. PT-353 Transmitter Parameter Codes (P Codes) (continued)
P
Code
Parameter
Binary Digits
Value
Description
P03
Term
B 0 0 0 0 0 0 0
0
0
DI-B multiplexer
1
Terminal or DI-A multiplexer
AUX
B 0 0 0 0 0 0
0
0
0
Not used; set to 0
B 0 0 0 0
0
0
0 0
0
Not used; set to 0
Input
sensitivity
B
0
0
0
0
0 0 0 0
0 or 1
Sets analog level control from +9dBu to
+24dBu (decimal levels 0-15; Table 4-4)
P04
B 0 0 0 0 0 0 0
0
0
Not used
1
Not used
ASRC
B 0 0 0 0 0 0
0
0
0
Asynchronous Sample Rate Converter is
disabled
1
Asynchronous Sample Rate Converter is
enabled
B
0
0
0
0
0
0
0 0
0
Not used
P05
B
0
0
0
0
0
0
0
0
0
Not used
Table 4-3. PR-353 Receiver Parameter Codes (P Codes)
P
Code
Parameter
Binary Digits
Value
Description
7 6 5 4 3 2 1 0
SRVC
Service
ON
Turn service on (enable module)
OFF
Turn service off (disable module)
P01
Time slot
B 0 0 0
0
0
0
0
0
0 or 1
Select the starting time slot using the five
least significant bits (LSBs):
●
1 to 24 in a T1 or variable rate
multiplexer where the selected slot is a
5-bit switch code + 1
●
0 to 31 in an E1 multiplexer where the
selected slot is a 5-bit switch code
B
0
0
0
0
0
0
0
0
0
Not used; set to 0
Summary of Contents for PT-353
Page 2: ......
Page 10: ...No header here 1 2 GatesAir Intraplex Products This page is left blank intentionally...
Page 30: ...No header here 3 16 GatesAir Intraplex Products This page is left blank intentionally...
Page 46: ...No header here 5 4 GatesAir Intraplex Products This page is left blank intentionally...
Page 50: ...No header here 6 4 GatesAir Intraplex Products This page is left blank intentionally...