Intraplex VF-25 Voice Module
3 – Installation
Version 7.1, November 2009
3-2
GatesAir, Inc.
Intraplex Products
ISiCL commands. Your multiplexer operation manual gives details on using the Intraplex
Simple Command Language (ISiCL) for remote access and control.
3.3 Mounting
Insert the module into the selected slot in the Intraplex multiplexer.
Warning!
The module must be inserted so that the white ejector tab is at the
bottom
in a full size
(5¼" high) shelf or at the
right
in a compact (1¾" high) shelf.
Table 3.1 Sample VF-25 Response to A CONFIG? Query
Response
Meaning
* OK
Valid command received.
CHANNEL CARD 4, TYPE
103
VF-25 module is in physical slot 4.
UNDER REMOTE CONTROL
Remote control is on.
SRVC = OFF
Service is off.
P01 = 12 (B00001100)
Four channels active, signaling on, using time slots 12, 13, 14, and 15.
P02 = 1 (B00000001)
Terminal operation, all loopbacks off.
P03 =124 (B01111100)
Ch. 1 Tx level control set to 0 dB.
P04 =124 (B01111100)
Ch. 1 Rx level control set to 0 dB.
P05 =124 (B01111100)
Ch. 2 Tx level control set to 0 dB.
P06 =124 (B01111100)
Ch. 2 Rx level control set to 0 dB.
P07 =124 (B01111100)
Ch. 3 Tx level control set to 0 dB.
P08 =124 (B01111100)
Ch. 3 Rx level control set to 0 dB.
P09 =124 (B01111100)
Ch. 4 Tx level control set to 0 dB.
P10 =124 (B01111100)
Ch. 4 Rx level control set to 0 dB.