NetXpress LX & CM-30R Installation & Operation Manual
4
–
Configuration & Operation
Version 1.1
4-86
GatesAir, Inc.
Intraplex Products
4.3.10.2 Sample Voice Module Configuration and Status
Figure 4-77. VF-25E Configuration Page
Alias Name:
The name you specify for the module to help identify the module type.
Shelf Name:
The name you specify for the multiplexer shelf housing the module.
Card Address:
Each module must have a unique address in the shelf. Valid addresses are 1 through
36.
TDM Bus:
The TDM bus on which the channel module resides.
Module Adapter:
The type of module adapter being used with the module.
Remote Control:
The mode of operation the module is set to use:
REMOTE
or
LOCAL
.
Enable Module:
Select this check box to place the module in service. If the check box is not selected,
the module is offline.
Module Configured:
Whether the module is properly configured.
TDM Bus Configuration
Timeslot:
The desired starting time slot (1 to 24 in T1 system, 1 to 31 in E1 system).
TDM Bus:
The current bus side, either Bus A or Bus B.
Active Channels:
Select the audio channels (1, 2, 3, 4) to enable them on the module. Each active
channel occupies one DS0 time slot.