5-1
Intraplex Products
Section 5 – Specifications
General
Operating Modes
System Compatibility
Four independent 4-wire voice channels
Two independent signaling paths in both directions per voice
channel
Compatible with Intraplex T1, E1, and IP access products
Compatible with Intraplex SynchroCast3 and SynchroCast
systems
Voice Frequency
Frequency Response
Channel Gain Accuracy
Input/Output Level
(Nominal)
Maximum
Input/Output Level
Fine Input/Output
Level Adjustment
Input/Output Impedance
Idle Channel Noise
Signal to Distortion
5Hz to 3000Hz, ±0.5dB
±0.2dB of nominal at 1004Hz
0 dBm, +7 dBm, or -16 dBm
Independently jumper selectable for input and output of each
voice channel
3dB greater than the selected nominal input or output level
Adjustment steps <.5dB
Adjustment range -6dB to +6dB
Available by remote control only
Balanced 600 ohms
Less than 26 dBrnC0
1004Hz input, 0 to -30 dBm: greater than 33dB in C message
weighting
Signaling
Contact Closure (E&M)
Signaling
Signaling Format
Two independent signaling lines in both directions for each of
the 4 voice channels. Ground on input (M lead) causes far-end
relay output (E lead) to change state. Both normally open and
normally closed outputs available for each signaling line.
Normally open contact use creates equivalent of E&M Type V
signaling.
In T1 systems: Robbed Bit A, B
In E1 systems: CAS