Intraplex VF-40 Voice Module
3 – Installation
Version 1.11
3-2
GatesAir
Intraplex Products
d.
Wait 15 seconds so that the parameter settings for the module are loaded into the shelf
common module.
e.
Remove the module and set to remote control: REMOTE switch DOWN. Do not turn service
on.
f.
Reinstall the module.
g.
Verify the configuration by remote control by issuing a
CONFIG?
query. Table 3-1 shows a
typical VF-40 response to a
CONFIG?
query.
h.
Set service On by remote control (ISiCL
SET
command, with
“SRVC = ON”
in the
parameter field). You can now change the operating parameters for the module using
ISiCL commands. Your multiplexer operation manual gives details on using the Intraplex
Simple Command Language (ISiCL) for remote access and control.
Table 3-1. Sample VF-40 Response To A CONFIG? Query
Response
Meaning
*OK
Valid command received.
CHANNEL CARD 4, TYPE 142
VF-40 module is in physical slot 4.
UNDER REMOTE CONTROL
Remote control is on.
SRVC = OFF
Service is off.
P01 = 3 (B00000011)
Starting time slot 12
P02 = 0 (B00000000)
Reserved
P03 = 1 (B00000001)
Terminal operation, all loopbacks off
P04 = 0 (B00000000)
Test tone off, four channels active, signaling on
P05 = 128 (B10000000)
Ch. 1 Tx level control set to 0 dB.
P06 = 128 (B10000000)
Ch. 1 Rx level control set to 0 dB.
P07 = 128 (B10000000)
Ch. 2 Tx level control set to 0 dB.
P08 = 128 (B10000000)
Ch. 2 Rx level control set to 0 dB.
P09 = 128 (B10000000)
Ch. 3 Tx level control set to 0 dB.
P10 = 128 (B10000000)
Ch. 3 Rx level control set to 0 dB.
P11 = 128 (B10000000)
Ch. 4 Tx level control set to 0 dB.
P12 = 128 (B10000000)
Ch. 4 Rx level control set to 0 dB.
P13 = 0 (B00000000)
Reserved for future use.
P14 = 0 (B00000000)
Reserved for future use.
3.3 Mounting
Insert the module into the selected slot in the Intraplex multiplexer.
Warning!
The module must be inserted so that the white ejector tab is at the bottom in a full size
(5¼" high) shelf or at the right in a compact (1¾" high) shelf.