BLEED AIR FROM SYSTEM
Tilt crimper forward so adapter is at its highest point.
Turn the knob on the controller to a setting of
400
,
which allows the ram to extend approximately 1”.
Turn pump on by pressing and holding the power
“on” switch, (see pump operating manual for switc
location) which extends the ram.
When the light comes on and buzzer sounds,
immediately release “on” switch allowing ram to
fully retract.
NOTE
: If light and buzzer are faint
do not work, the controller batteries may need
replacement. See “Maintenance” section of this
manual. Repeat a minimum of five (5) times to bleed
air completely.
PLACE CRIMPER IN COMFORTABLE
WORKING POSITION
See photo below for suggested working
7.
CAUTION
Keep away from all moving parts!
If bodily contact with a moving part occurs,
immediately release the pump power “on” switch.
IMPORTANT
Do not operate crimper in horizontal position
because dies will become unstable.
THINK SAFETY
NOTE: It’s a good idea to place a rubber mat on
the floor near the crimper to reduce the chance
of damaging a die if dropped and improve
operator comfort.
8.
7
SETUP
MOBILE CRIMP 4-20 SAFETY AND OPERATING MANUAL