9/5/2007
11
Fig. 3
WARNING- CLOSING THE CRIMPER HEAD ON THE QUICK CHANGE TOOL WILL
DAMAGE THE QUICK CHANGE TOOL.
C. Installing the GC32 die set into the GC96 Crimper
•
Using the Gates Quick Change Tool (QCT), select dies from the storage
receptacle.
•
Align die finger dovetails with
die shoe receptacles on GC96 spacer dies installed
in crimper head.
•
Press the QCT in until it bottoms out on the die shoe surface. The die is then
set.
•
Release the QCT by twisting to the left, or counterclockwise, until die fingers are
disengaged.
•
Withdraw the QCT.
D. Unloading GC32 standard die sets using the QCT
•
Perform step A & B above to position the head to accept the QCT.
•
Press the Quick Change Tool (QCT) in until it bottoms out on the die shoe
surface.
•
Twist QCT clockwise until die fingers are engaged and withdraw QCT. This will
pull the die fingers out of the crimper head.
•
Press die fingers back into storage receptacle.
•
Twist QCT handle counterclockwise to unload die fingers.
•
Withdraw QCT.
GC96 Display Panel Operation
After applying power to the GC96, the control panel will load the “MAIN WORKING
DISPLAY”. This takes several seconds to load. The Control Panel is TOUCH SCREEN
therefore the designated circles on the screen perform as functional buttons. There are
two main tabs on the TOUCH SCREEN panel CRIMP and OPTIONS. Functionality
described below.
Note- The GC96 Touch Screen can ‘freeze’ in start up. If this happens, turn off the
crimper for 5 minutes then return and try again. If the problem persists, call Gates
Product Application.
Gates Hose Product application phone number: 303-744-5070
Summary of Contents for GC96