background image

36

Accessories

POWERING ACCESSORIES

Low Voltage Wire

 [RB509] 

The 16 gauge, stranded, dual conductor low voltage Wire is for connecting the AC powered 

transformer, solar panel or wired accessories to the system’s control board. This specially 

designed wire is UV treated, PVC coated, and ready for direct burial.

Solar Panel Kits

 [FM122/FM123]

If your gate operator is more than 1000 ft. away from an AC power outlet, you can choose to 

maintain the battery charge with the GTO Solar Panel Kit.
 

•  10 Watt Solar Panel Charging Kit [FM123] 

 

•  5 Watt Solar Panel Charging Kit [FM122] 

Additional/Replacement Battery

 [RB500]

For additional battery power or replacement.

“FROM VEHICLE” ENTRY AND EXIT ACCESSORIES

Transmitters

 [RB741/RB742/RB743]

Purchase an additional transmitter for each vehicle in your family. The Two-Button 

Transmitter can be programmed to operate both your gate operator and a garage door 

opener using the Universal Receiver. Or it can be programmed to open two gate operator 

systems.
 

•  Single Button Transmitter [RB741] 

 

•  Dual Button Transmitter [RB742]

 

•  Three Button Transmitter [RB743] 

Universal Receiver

 [RB709U-NB]

The Universal Antenna Receiver gives you the ability to use one remote to activate your 

gate operator and your garage door opener. Connects to any brand garage door opener. Up 

to 100 ft. range.

Digital Keypad

 [F310]

Allow friends access to your property using an identification code that you provide. 

Program up to 25 entry codes for added security. Powered by three “AA” batteries (not 

included).

Please visit www.gtoaccess.com for  photos and detailed descriptions of GTO 

Accessories. Or call 1-800-543-GATE (4283).

1

2

ABC

3

DEF

4

GHI

5

JKL

6

MNO

7

PRS

8

TUV

9

WXY

0

Summary of Contents for Silver-HD Single

Page 1: ...thereafter The installer and or user agree to assume responsibility for all liability and use of this product releasing Gates That Open LLC from any and all liability If you are not in agreement with...

Page 2: ...Class I Residential Vehicular Gate Operator and is intended for use solely with vehicular swing gates in single family residential applications This Gate Operator is system certified to be in complian...

Page 3: ...nstallation____________________________________________________ 19 Receiver Installation_____________________________________________________________ 21 SOLAR PANEL INSTALLATION_______________________...

Page 4: ...tic gate locks and other access control products These optional accessories are sshown in the back of this manual The gate operator features adjustable stall force This safety feature makes the gate s...

Page 5: ...when the opener is disconnected manual cannot be completely exhaustive in nature They do however provide an overview of the safe design installation and use of this product CAREFULLY READ AND FOLLOW A...

Page 6: ...nstalled and swings freely in both directions Repair or replace all worn or damaged gate hardware prior to installation A freely moving gate will require less force to operate and will enhance the per...

Page 7: ...m below Never install any control device where a user will be tempted to reach through the gate to activate the gate opener 5 Do not activate your gate opener unless you can see it and can determine t...

Page 8: ...te and gate operator regularly Grease hinges clean the push pull tube by spray ing a soft dry cloth with silicone spray and wipe the tube at least once per month and replace the battery every 2 3 year...

Page 9: ...apment protection Also the gate opener has provisions for the connection of Type B1 or B2 protection to be used as the secondary type of entrapment protection if desired 1 For gate operators utilizing...

Page 10: ...tive enough to prevent bodily injury in some circumstances For this reason safety devices such as safety edge sensors or photoelectric sensors which stop and reverse gate direction upon sensing an obs...

Page 11: ...play in gate area 3 This gate is for vehicles only Pedestrians must use separate entrance WARNING MOVING GATE Can Cause Injury or Death 1 800 543 4283 ANNIVERSARY SERIES www gtoaccess com HEAVY DUTY...

Page 12: ...o 120 s and obstruction sensitivity Power terminal block accommodates a transformer or solar panels NOTE Do not use solar panel and transformer at the same time DIP switches simplify setup of gate ope...

Page 13: ...od not recommended for solid surface gates Pull to Open Option Instructions begin on page 13 Push to Open Option Instructions begin on page 16 A Level B Plumb C Free Swinging 9 For the gate opener to...

Page 14: ...y O r D e a t h W A R N I N G A H I K D F B G C J E L M Q W S R O N P T V U X Y Z 3 8 Bushing 2 3 8 x 2 3 4 Bolt 2 Gate Bracket A The simplest solution is to install the opener in a push to open confi...

Page 15: ...log Do not use both transformer and solar If you have thin walled tube or panel gates see Recommended Reinforcement Examples in Quick Reference Guide after Step 3 of Mounting Opener to Gate section De...

Page 16: ...binding by inspecting alignment TIP Turning the pivot bracket over gives more hole alignment options for the post pivot bracket assembly Remove clevis pin from the gate bracket and support loose opene...

Page 17: ...5 in both open and closed positions Mark middle of post bracket slots on fence post Mark middle of gate bracket slots on gate cross support Remove clamps post gate brackets and opener Then use a hamm...

Page 18: ...t excess length on post and gate bracket with hacksaw Your Property 12 Y S T R 1 1 2 2 13 14 15 2 1 1 2 Fully open gate Attach gate stop with one of the following U bolts tube and chain link gates Not...

Page 19: ...post pivot bracket assembly With gate in CLOSED position using clamps secure opener to gate post and center cross member of gate Gate Opener Installation Recommended reinforcement and gate bracket mou...

Page 20: ...t slots on fence post Mark middle of gate bracket slots on gate cross support 10 Remove clamps post gate brackets and opener Then use a hammer and center punch to mark hole positions Drill holes compl...

Page 21: ...lt excess length on post and gate bracket with hacksaw 12 Y S T R 13 2 1 2 1 14 15 2 1 1 2 Fully open gate Attach gate stop with one of the following U bolts tube and chain link gates Not included Woo...

Page 22: ...ONTROL INPUTS MASTER CABLE SLAVE CABLE CONTROL INPUTS AUTO CLOSE TIME STALL FORCE CLO SE EDG E 18 VAC or SOLAR GTO LOCK AUX 1 2 3 4 5 6 7 R B 5 0 0 1 2 V o lt 7 0 Am p M ou nt 15 FUSE BATT BATT 1 2 3...

Page 23: ...esponding color terminals CAUTION Please call your power company before you dig Failure to do so could cause injury or even death 10 Top View Min 3 Ft Max 1 000 Ft GTO Transformer Mounts Here 9 Locate...

Page 24: ...LK GRN WHT BLU BRN ORG RED BLK GRN COM MASTER OPERATOR 2ND OPERATOR 1 2 3 4 5 6 7 POWER INPUT LOCK PWR AUX RLY CONTROL OUTPUTS GTO 18VOLT TRANSF OR SOLAR PANEL POWER INPUT LOCK PWR AUX RLY CONTROL OUT...

Page 25: ...to fence or post NOTE If mounting on metal fence mount receiver on a piece of wood DO NOT mount upside down Control Box Installation Receiver Installation Tips 1 Mount the receiver high and above any...

Page 26: ...for winter minimum sunlight and do not account for the use of any accessory items Accessories connected to your system will draw additional power from the battery NOTE A minimum of 5 watts of solar c...

Page 27: ...8 VAC or SOLAR GTO LOCK AUX 1 2 3 4 5 6 7 15 FUSE BATT BATT 1 2 3 4 O N STATUS LEARN RMT RECEIVER LEARN MAST LIMIT LEARN SLV LIMIT S3 S4 ALM S2 OFF SOFT START OFF WARNING OFF OPEN PULL SLV OPEN DLY MO...

Page 28: ...2 3 4 1 2 3 4 ON DIP Switch 1 Soft Start Stop The soft start stop feature slowly starts the gate as it begins to open or close and slows the gate as it comes to the opened or closed position This save...

Page 29: ...S CONTROL INPUTS MASTER CABLE SECOND CABLE CONTROL INPUTS AUTO CLOSE TIME STALL FORCE CLO SE EDG E 18 VAC or SOLAR GTO LOCK AUX 1 2 3 4 5 6 7 1 2 3 4 ON LEARN MAST LIMIT LEARN 2nd LIMIT S3 S4 S2 OFF S...

Page 30: ...N MAST LIMIT LEARN SLV LIMIT S3 S4 ALM S2 OFF SOFT START OFF WARNING OFF OPEN PULL SLV OPEN DLY MODE1 OFF MODE2 OFF ON ON PUSH SIMULT ON ON 120 MIN MAX CHARGING PWR IN GTO RCVR WH T BLU BRN ORG RED BL...

Page 31: ...EARN MAST LIMIT LEARN SLV LIMIT S3 S4 ALM S2 OFF SOFT START OFF WARNING OFF OPEN PULL SLV OPEN DLY MODE1 OFF MODE2 OFF ON ON PUSH SIMULT ON ON 120 MIN MAX CHARGING PWR IN GTO RCVR WH T BLU BRN OR G RE...

Page 32: ...F OPEN PULL SLV OPEN DLY MODE1 OFF MODE2 OFF ON ON PUSH SIMULT ON ON 120 MIN MAX CHARGING PWR IN GTO RCVR WH T BLU BRN OR G RED BLK GR N WH T BLU BRN OR G RED BLK GR N CO M GRN BLK RED CYC LE SAF ETY...

Page 33: ...es and national and regional safety codes Call GTO Sales at 1 800 543 4283 for information on compatible products for your specific application PLEASE NOTE Contact Sensors Non Contact Sensors and Shad...

Page 34: ...ctivation of this input while gate at the fully open position will prevent gate from closing 6 CLOSE EDGE Typically for use with safety edge device Activation of this input while the gate is closing w...

Page 35: ...Edge Sensor NOTE Connections are for typical applications There may be additional connection options for applications that are not illustrated here 2 1 1 3 1 4 Keypad 1 1 2 1 2 ABC 3 DEF 4 GHI 5 JKL 6...

Page 36: ...Wire from Automatic GTO Lock GTO LOCK Connecting GTO Automatic Lock Connecting Additional Devices GTO Lock Connection Connect the red and black leads from the lock to the GTO LOCK terminal on the gat...

Page 37: ...Battery Harness Connections Battery Under Load 1 beep then 2 beeps Master Motor Terminals Shorted Connections to Master Inputs Master Arm Power Cable Motor Circuit Board 1 beep with 2 seconds off Mas...

Page 38: ...other accessory wired to this terminal Try the remote If the remote works the problem is the accessory Status clear 6 blinks Open Edge Terminal Shorted Disconnect edge sensor photo beam or any other...

Page 39: ...ation RGA number in LARGE BOLD PRINT on the outside of the package WILL NOT be accepted Also items returned to GTO freight collect WILL NOT be accepted Repair Service GTO Technical Service and Install...

Page 40: ...additional transmitter for each vehicle in your family The Two Button Transmitter can be programmed to operate both your gate operator and a garage door opener using the Universal Receiver Or it can b...

Page 41: ...n transmitter and receiver Easy installation LOCKING SECURITY Accessories Automatic Gate Lock FM144 FM142 The 1 Accessory For Swing Gate Operators Designed for added security in conjunction with GTO A...

Page 42: ...ries Photo Beams R4222 Primary through beam photo beam device Provides non contact entrapment protection Pin Lock FM345 Use as a substitute for the clevis pin at the front mount of the gate opeator to...

Page 43: ......

Page 44: ...rtsfield Road Tallahassee Florida USA 32303 Telephone GTO Sales 1 800 543 GATE 4283 or 850 575 0176 Fax 850 575 8912 or GTO Technical Service 1 800 543 1236 or 850 575 4144 Fax 850 575 8950 www gtoacc...

Reviews: