background image

REVISION 2019-2

GateMotors: +44 (0)1202 744958 • Technical support: +44 (0)1202 725489
www.gatemotors.co.uk • Sales and Accessories: +44 (0)1202 717191

If the ideal scenario of 
measurements 

A

 and 

B

 (above) 

is unachievable then refer to 
the below tables to determine 
the position and mounting hole 
selection for bracket 

T1

.

D

200 mm

175 mm

150 mm

125 mm

100 mm

75 mm

50 mm

25 mm

0 mm

A

140 mm

170 mm

200 mm

195 mm

190 mm

185 mm

210 mm

235 mm

260 mm

B

150 mm

225 mm

200 mm

205 mm

210 mm

215 mm

190 mm

165 mm

140 mm

Bracket quota

50 mm

50 mm

50 mm

80 mm

110 mm

140 mm

140 mm

140 mm

140 mm

Minimum leaf length

1030 mm

1000 mm

980 mm

990 mm

990 mm

970 mm

970 mm

950 mm

930 mm

m

yA

st

er

 4

D

225 mm

200 mm

175 mm

150 mm

125 mm

100 mm

75 mm

50 mm

25 mm

A

225 mm

250 mm

245 mm

240 mm

235 mm

260 mm

285 mm

310 mm

335 mm

B

275 mm

250 mm

255 mm

260 mm

265 mm

240 mm

215 mm

190 mm

165 mm

Bracket quota

50 mm

50 mm

80 mm

110 mm

140 mm

140 mm

140 mm

140 mm

140 mm

Minimum leaf length

1150 mm

1130 mm

1130 mm

1130 mm

1140 mm

1120 mm

1100 mm

1070 mm

1050 mm

m

yA

st

er

 5

D

275 mm

250 mm

225 mm

200 mm

175 mm

150 mm

125 mm

100 mm

75 mm

A

275 mm

300 mm

295 mm

290 mm

315 mm

310 mm

335 mm

360 mm

385 mm

B

325 mm

300 mm

305 mm

310 mm

285 mm

290 mm

265 mm

240 mm

215 mm

Bracket quota

50 mm

50 mm

80 mm

110 mm

110 mm

140 mm

140 mm

140 mm

140 mm

Minimum leaf length

1300 mm

1240 mm

1280 mm

1260 mm

1260 mm

1270 mm

1240 mm

1220 mm

1200 mm

m

yA

st

er

 6

D

150 mm

125 mm

100 mm

75 mm

50 mm

25 mm

0 mm

A

100 mm

125 mm

150 mm

145 mm

140 mm

135 mm

160 mm

B

200 mm

175 mm

150 mm

155 mm

160 mm

165 mm

140 mm

Bracket quota

50 mm

50 mm

50 mm

80 mm

110 mm

140 mm

140 mm

Minimum leaf length

880 mm

860 mm

840 mm

840 mm

850 mm

850 mm

830 mm

m

yA

st

er

 3

90º

Pillar bracket T1

How to determine fixing dimensions

Position the bracket 

T1

 using the measurement 

A

 and 

B

 as indicated  

in the below table for an inward opening angle of 

90°

 (pic E).

(pic E)

myAster 3

myAster 4

myAster 5

myAster 6

A

150 mm

200 mm

250 mm

300 mm

B

150 mm

200 mm

250 mm

300 mm

D

125 mm (max.)

175 mm (max.)

225 mm (max.)

275 mm (max.)

(Table A)

Summary of Contents for MyGate myAster 3

Page 1: ...VISION 2019 2 automationKitforswinggates myAster GateMotors 44 0 1202 744958 Technical support 44 0 1202 725489 www gatemotors co uk Sales and Accessories 44 0 1202 717191 ENGLISH Installation Manual...

Page 2: ...move all manual locks and bolts In the event of a power cut the gate motor can be released by manual operation Use of the product must be restricted to its intended use Any other use is to be consider...

Page 3: ...screw RECOMMENDED GATE LEAF FIXINGS not included GateMotors 44 0 1202 744958 Technical support 44 0 1202 725489 www gatemotors co uk Sales and Accessories 44 0 1202 717191 myAster dimensions 50 mm 11...

Page 4: ...00 rpm 1400 rpm Leaf s maximum length 2000 mm 2000 mm 2500 mm 2750 mm 3000 mm 3500 mm 4000 mm Leaf s maximum weight 275 Kg 350 Kg 250 Kg 350 Kg 150 Kg 250 Kg 250 Kg Maximum opening 110 110 110 110 110...

Page 5: ...mm Left motor Right motor INWARD FACING Check that the open position of the automated gate is not an entrapment hazard with regards to any surrounding buildings or fixed objects and there is sufficie...

Page 6: ...m 140 mm 140 mm Minimum leaf length 1150 mm 1130 mm 1130 mm 1130 mm 1140 mm 1120 mm 1100 mm 1070 mm 1050 mm myAster 5 D 275 mm 250 mm 225 mm 200 mm 175 mm 150 mm 125 mm 100 mm 75 mm A 275 mm 300 mm 29...

Page 7: ...ecreased by the same amount as the A measurement is increased For example If installing the myAster 3Ti measurement A increasing 20 mm now 170 mm means measurement B ideally decreases 20 mm now 130 mm...

Page 8: ...ill return to its default settings Manual release NB Check the manual opening of the gate leaf before definitively fixing the bracket S3 to make sure the gate can open fully to your required angle To...

Page 9: ...conduits for the electrical cables feed the motors control panel and accessories separately in order to prevent interferences that may result in bad operation Fit the power cable keeping a curve as s...

Page 10: ...ent removal tampering of any labels attached to the product will invalidate the warranty Transferring the warranty to any other person The warranty is only applicable to the original purchaser Under n...

Page 11: ...er operated doors Requirements EN 12445 Industrial commercial and garage doors and gates Safety in use of power operated doors Test methods EN60335 1 Safety of household and similar electrical applian...

Page 12: ...make and model Serial number INSTALLER DETAILS Company name Installer Telephone number Signature Date COMMISIONER DETAILS Name Signature Date GateMotors 44 0 1202 744958 Technical support 44 0 1202 7...

Reviews: