GTC-700 Series Analog Mux Controller has various built-in functions and equipped with micro-processor and high 

resolution A/D converter. GTC-700 is constructed as central studio system and consists of one common unit that 

performs collection and display of measurement data and data communication and a 8-channel analog input unit that 

measures analog input signal (0 - 20 mA). Analog input unit can be expanded up to 16-channels depending on the 

service environment.

GTC-700 Series is built with FND digital display (mA value) and LED that displays status of analog input channel, 

operation status of internal network, and power on status for the main power. It has RS-485 port and Ethernet port for 

data network.

3.1. Basic Specification (Based on 128 Channel)

ITEMS

SPECIFICATION

Input Signal

Analog 4-20mA ( 0~ 20mA )

Input Voltage

Absolute min:
Nominal:
Absolute max:
Ripple maximum allowed:

18V
24V
30V
1V pk-pk

Max. Wattage

Common Unit

58mA@24VDC( normal )

Analog Unit

32mA@24VDC( normal )

For 128-channel configuration

595mA@24VDC( normal )

Max. Wattage

Common Unit

1.39W@24VDC ( normal )

Analog Unit

0.768W@24VDC ( normal )

For 128-channel configuration

14.28W @24VDC ( normal )

Measuring Value Display

Common Unit

4-Digit Seven Segment x 2

Analog Unit

Power, Error, Status LED

Output Signal

Isolation RS-485 MODBUS, MODBUS TCP/IP

Cable Connection Length and Wire Requirement

Power

Approx. 40 m when CVVS,CVVSB 
with shield AWG23 are used.

RS485

STP (Shielded Twisted Pair)
Max. 1 km

TCP/IP

CAT5 cable or equivalent RJ45
Max. 100m

Approval

CE

3.2. Mechanical Specifications (Based on 128 Channel)

ITEMS

SPECIFICATION

Dimension

593.5(W) x 132.5(H) x 120(D) mm

Weight including Sensor

App. 4.7kg

Mounting Type

Wall mount

Body Material

aluminum alloy

3.3. Environmental Specifications

ITEMS

SPECIFICATION

Operation Temperature

0 to 55 ℃

Storage Temperature

0 to 55 ℃

Operation Humidity

5 to 99% RH (Non-condensing)

Pressure Range

90 to 110KPa

GTC-700 Series Analog Multiplexer Controller is convenient to build the monitoring system with RS-485 & Ethernet 

network. It can construct max. 128 detectors with 1 set of controller. It enables expansion of controller to construct 128 

or more detectors. (Max. 32 sets, 4096 channels)

Analog input (0 - 20 mA) port is grounded to protect the system safely in an event of thunderbolt or surge. It is equipped 

with high performance microprocessor to scan 128-channels within 1 sec (0.64 sec). Each channel can be span calibrated 

for accuracy of measurement and calibrated to compensate the cable route.

2. Characteristics

GTC-700

Instruction Manual

1. Overview

3. Specification

Summary of Contents for GTC-700

Page 1: ...ce d Industry 1 ro Bugok dong Gunpo si Gyeonggi do Tel 82 31 490 0800 Fax 82 31 490 0801 Yeongnam business office Plant 55 Gonghangap gil 85beon gil Gangseogu Busan Metropolitan City Tel 51 973 8518 F...

Page 2: ...ormed quarterly when the calibration period is not specified The product and manual are subject to change without a notice for the product s functional improvement and ease of use For accurate operati...

Page 3: ...onmental Specifications 7 4 Name and Description of Each part 8 4 1 External Components 8 4 2 Internal Components 10 5 Installation 11 5 1 Power and External Signal Configuration 11 5 2 Channel Config...

Page 4: ...e Display Common Unit 4 Digit Seven Segment x 2 Analog Unit Power Error Status LED Output Signal Isolation RS 485 MODBUS MODBUS TCP IP Cable Connection Length and Wire Requirement Power Approx 40 m wh...

Page 5: ...ights on when power turns on 16 Main Power Switch Power ON OFF Switch 17 Analog Input Channel Status LED It displays measurement status Orange light turns on below 3 9 mA Green light turns on between...

Page 6: ...24 V Connected to the external power supply V terminal for device power supply provides normal 24 V Connected to the external power supply FG Frame Ground terminal that is connected to the power suppl...

Page 7: ...125 125 CH 16 5 126 126 CH 16 6 127 127 CH 16 7 128 128 CH 16 8 Channel configuration per slot is as shown in the table below www gastron com 12_13 5 Installation 5 Installation GTC 700 Instruction Ma...

Page 8: ...e with CVVSB 0 7 sq or higher Check wirings for operation power detection parts alarm parts and concentration display Check the power input then turn ON the power S W Check whether power LED at alarm...

Page 9: ...w 4 mA green lights on for values in a range of 4 mA 20 mA and red lights on for values exceeding 20 mA Table 6 Operation Setting Mode Default Settings LEVEL1 LEVEL2 LEVEL3 DEFAULT F1 CONF Configurati...

Page 10: ...tion menu Pressing FUNC key changes to the initial menu page F1 CONF www gastron com 18_19 GTC 700 Instruction Manual When FUNC key is pressed for 2 sec or longer in measuring mode it enters password...

Page 11: ...an move between channels 1 1 16 8 for calibration Pressing RESET key moves to the previous step Using a current generator input 20 mA output into the analog input terminal positive negative of the cha...

Page 12: ...clockwise direction in an order For LED of analog input unit power status LED lights on and Error Com Channel Red Green Status LEDs flash in an order Pressing FUNC key ends the test and moves to the...

Page 13: ...nge during menu setting It displays the end of the selected menu After approx 1 sec it moves to the initial menu for network setting Pressing FUNC key for 2 sec or longer followed by password input en...

Page 14: ...r DOWN key to select between 0 255 Pressing FUNC key sets the selected address and moves to the next address setting menu It is the second subnet mask setting menu Use UP or DOWN key to select between...

Page 15: ...d moves to the next address setting menu It is the fourth gateway setting menu Use UP or DOWN key to select between 0 255 Pressing FUNC key sets the selected address and moves to the next address sett...

Page 16: ...lue between 00 FF hexadecimal When there is a change it returns to the selected menu To complete the change of setting use UP or DOWN key in the selected menu to select UP y If the change is not wante...

Page 17: ...ion Unsigned Integer Refer to section 9 Error code Heart bit 30191 Repeats 0 and 1 Unsigned Integer 30192 Increase by 1 Unsigned Integer Table 8 Fault List MESSAGE VALUE DESCRIPTION CONDITION RECOVERY...

Page 18: ...www gastron com 34_35 GTC 700 Instruction Manual Figure 8 GTC 700 Drawing VERSION CONTENTS DATE 1 0 Initial Revision of Manual 2016 10 05 10 Revision History 9 Drawings and Dimensions...

Reviews: