To connect the machine to the electric network it is necessary to proceed as follows:
1)
connect to the wires to the terminals L1
—
L2
—
L3
—
N
—
of power cord type
H07RNF 3G X “x”
mm
²
unsheathed with ferule;
2)
put together the other end of the cable and a plug, which is normalised and polarised (the
distinction between phase and neutral must be unequivocal.
3)
to connect the oven to 230 V single phase is sufficient to make a bridge between L1-L2-L3 with
the special plates present in the terminal box
ELECTRIC
CONNECTION
THE ELECTRIC CONNECTION OF THE OVEN TO THE MAINS MUST BE
COMPULSORILY AND EXCLUSIVELY PERFORMED BY AN AUTHORIZED
TECHNICIAN (ELECTRICIAN) SATISFYING THE TECHNICAL AND PROFESSIONAL
REQUIREMENTS STATED BY THE REGULATIONS IN FORCE IN THE COUNTRY OF
USE OF THE OVEN, WHO MUST ISSUE A DECLARATION OF CONFORMITY FOR
THE INTERVENTION PERFORMED.
FOR DIRECT CONNECTION TO THE NETWORK, YOU MUST HAVE A DEVICE THAT
HAS A CONTACT GAP TO ENSURE THE COMPLETE DISCONNECTION, IN THE
CONDITIONS OF OVERVOLTAGE CATEGORY III, IN ACCORDANCE WITH THE
RULES FOR INSTALLATION.
L1 Clamp N.1
L2 Clamp N.2
L3 Clamp N. 3
N Clamp N. 4 or N. 5
Clamp N. 6
ONCE THE ELECTRIC CONNECTION HAS BEEN PERFORMED, THE AUTHORIZED
TECHNICIAN (ELECTRICIAN) MUST ISSUE A DECLARATION CERTIFYING THE
MEASUREMENT OF THE CONTINUITY OF THE EQUIPOTENTIAL PROTECTION
CIRCUIT.
THE APPLIANCE IS TO BE SUPPLIED THROUGH A RESIBASIC CURRENT DEVICE
(RCD) HAVING A RATED RESIBASIC OPERATING CURRENT NOT EXCEEDING 30
MA
Summary of Contents for MILAN Series
Page 1: ...ENGLISH INSTRUCTIONS FOR USE AND MAINTENANCE ELECTRIC OVENS FOR PIZZA MILAN ROME NAPELS...
Page 2: ...REV 03 19 06 2018 OVEN ENGLISH...
Page 13: ...12 SPARE PARTS ONE CHAMBER OVEN EXLODED VIEW...
Page 14: ...13 TWO CHAMBER OVEN EXLODED VIEW...
Page 15: ...14 DOOR EXPLODED VIEW...
Page 16: ...15...
Page 17: ...16 CONTROL UNIT EXPLODED VIEW...
Page 20: ...19 WIRING DIAGRAMS MILAN ROME 400V 3PH one chamber...
Page 21: ...20 MILAN ROME 230V 1PH one chamber...
Page 22: ...21 MILAN ROME 230V 3PH one chamber...
Page 23: ...22 NAPELS 400V 3PH one chamber...
Page 24: ...23 NAPELS 230V 1PH one chamber...
Page 25: ...24 NAPELS 230V 3PH one chamber...
Page 26: ......