Gassonic Observer-i HART
18
10.12 COMMAND #150: READ CLOCK
This command reads the internal real-time clock setting.
Request Data Bytes
Byte
Format
Description
0 N/A
N/A
Response Data Bytes
Byte
Format
Description
0 – 2
Date
Date: Day, Month, Year-1900
3 Unsigned-8 Hours
4 Unsigned-8 Minutes
5 Unsigned-8 Seconds
Command-Specific Response Codes
Code
Class
Description
0
Success
No Command-Specific Errors
1-127
Undefined
10.13 COMMAND #151: SET RUN TIME METER
This command sets the internal run time meter.
Request Data Bytes
Byte
Format
Description
0 – 3
Unsigned-32
Run Time Meter Value
Response Data Bytes
Byte
Format
Description
0 – 3
Unsigned-32
Run Time Meter Value
Command-Specific Response Codes
Code
Class
Description
0
Success
No Command-Specific Errors
1 – 4
Undefined
5
Error
Too Few Data Bytes Received
6 – 127
Undefined