Gassonic Observer-i HART
22
18-21 Float
Peak
dB
Command-Specific Response Codes
Code
Class
Description
0
Success
No Command-Specific Errors
1-127
Undefined
10.19 COMMAND #164: GET SLOW CHANGING INFORMATION
This command is used to collect data from the Observer
-i
which is likely to change at a very slow rate.
Request Data Bytes
Byte
Format
Description
None N/A
N/A
Response Data Bytes
Byte
Format
Description
0 - 1
Signed-16
Unit Temperature
2 - 5
Float
Supply Voltage
6 - 7
Signed-16
Reserve
Command-Specific Response Codes
Code
Class
Description
0
Success
No Command-Specific Errors
1-127
Undefined
10.20 COMMAND #165: GET SET UP INFORMATION
This command reads the setup information in the Observer
-i
.
Request Data Bytes
Byte
Format
Description
None N/A
N/A
Response Data Bytes
Byte
Format
Description
0
Unsigned-8
N/A