15
GSR-M10-DC/M, GSR-M12-DC/M, GSR-M14-DC/M, GSR-M16-DC/M, GSR-M10-DC/T, GSR-M12-DC/T, GSR-M14-DC/T,
GSR-M16-DC/T
8.
Installation Guideline of Monobloc
Unit
8.1.
Instruction to installation
1. Installation of the unit must be in accordance with national and local safety codes.
2. Installation quality will directly affect the normal use of the air conditioner unit. The user is prohibited
from installation. Please contact your dealer after buying this machine. Professional installation workers
will provide installation and test services according to installation manual.
3. Do not connect to power until all installation work is completed.
4. The foot brackets of the compressor is used to reduce vibration during transport. Before commissioning,
they must be removed, otherwise it would lead to unnecessary faults. When foot brackets have been
removed, the fastening screws must be tightened so as to prevent the compressor from jumping out
during operation.
8.2.
Installation of monobloc unit
8.2.1. Selection of installation location of monobloc unit
1. Monobloc unit must be installed on a firm and solid support.
2. Avoid placing the monobloc unit under window or between two constructions, hence to prevent normal
operating noise from entering the room.
3. Air flow at inlet and outlet shall not be blocked.
4. Install at a well-ventilated place, so that the machine can absorb and discharge sufficient air.
5. Do not install at a place where flammable or explosive goods exist or a place subject to severe dust, salty
6. fog and polluted air.