13
6.
Installation Example
CASE 1:
Connecting Under-floor Coil for Heating and Cooling
Shut off value
Remote room Thermostat
(Field supply)
By-pass value
(Field supply)
3-wa y value
High temperature line
Low t emperature line
Notes
(a)Type of thermostat and specification should be complied with installation of this manual;
(b)By pass valve must be installed to secure enough water flow rate,and by pass valve should be
installed at
the collector.
Notes
(a)In this case, three-way valve should be installed and should be complied with installation of this manual;
(b)Sanitary should be equipped with internal electric heater to to secure enough heat energy in the very
cold days.
Sanitary water tank
Under-floor coil
Under-f loor coil
CASE 2:
Connecting Sanitary Water Tank and Under-floor Coil
High temperature line
Low t emperature line
Shut off value
Remote room Thermostat
(Field supply)
By-pass value
(Field supply)
Booster heater