USE AND MAINTENANCE
ENGLISH
g
cod. G19502880
52
4.7 ALARM MESSAGES
If the system is not working properly, the following checks can be carried out to understand whether service is required. If the problem
persists even after the recommended checking, address the local dealer and report the problem to the Manufacturer using the
“Report form” in the last page of this manual.
WARNING
The use of mobile phones, HAM radio systems or work near magnetic fields (high voltage electricity pylons) may jeopardise
correct system operation.
Figure 62 illustrates the screen which appears when an alarm triggers.
The operator is warned about a problem through a message on the alarm screen, where useful information is also displayed.
Press the function button
to clear the displayed alarm and reset the display to the original status, or to move on to another
alarm, if more than one alarm has triggered.
There are three alarm levels according to priority:
HIGH PRIORITY
1 -Module offline;
2 -Module temperature;
3 -Module overload.
MEDIUM PRIORITY
1 -Motor speed;
2 -Shaft confirmation;
3 -Encoder failure.
LOW PRIORITY
1 -Low/High fan speed;
2 -Cardan speed;
3 -Hopper level low.
NOTE: if several alarm trigger simultaneously, they are displayed according to priority level.
ALARM
DESCRIPTION
ALARM: MODULE MCM OFFLINE
Indicates that the control unit does not
sense connection of module MCM.
SOLUTION
fig. 62
ALARM: MODULE HBM OFFLINE
Indicates that the control unit does not
sense connection of module HBM.
- Check the electrical connections of
the system and inside the main
electrical panel.
- Check the electrical connections of the
system and inside the main electrical
panel.
ALARM: MODULE MCM TEMPERATURE
Indicates that the temperature of the
motor control module is excessively
high.
- Check that the metering units and/or
motor turn freely.
- Module MCM may be malfunctioning.
- The motor may be malfunctioning.
Tabella 9