VRT Hydraulic Drive
– Calibration
Page 22
10/09
Fig. 27 Rates Screen.
7. When in the calibration screen (refer Fig.28)
you will need to set the following:-
a)
‘CAL SPEED’. This is the speed at which the
metershaft rotates during the calibration test
(1-10). Refer Table 30. The
default setting
is 4
. The higher the setting the faster the
speed.
b)
‘TEST PULSES’. The number of pulses to
run the test (generally 600 for Pasture
Planter). The bigger the sample the better.
c) When complete push the soft key under the
‘READY’ prompt before leaving the cab. Test
pulses will now be displayed as zero and will
record feedback from the seeder.
Fig. 28 Product Calibration Screen.
8. To begin calibration procedure at the
seeder:-
a)
Engage tractor’s hydraulic circuit to run the
air seeder. The fan should not run because
the flow control valve at the fan is turned off.
b) Open the bottom door on the Pasture Planter
meterbox.
c) Fit the calibration sample bag to the bottom
of the Pasture Planter meterbox.
d) Prime the system to ensure that the new
product is fully surrounding the meterwheels.
To do this, push the green button on the
calibration control box on the seeder. Allow
meterwheels
to
rotate
a
couple
of
revolutions.
PUSH THE RED BUTTON TO
STOP
. This will stop the meter system and
zero the ‘TEST PULSES’ count when the
green button is next pushed.
Fig. 29 Calibration control box.
e) Empty sample bag and refit for the full
calibration run.
9. Push the green button to start calibration
test.
10. Allow system to stop by itself. If the sample
bag fills or a larger sample is required,
change the ‘TEST PULSES’ setting at
monitor. It will be necessary to go back one
screen and re-enter the Product Calibration
screen before making changes to the ‘TEST
PULSES’ value. Push ‘READY’ prompt again
and re-run test at the seeder.
11. After a correct sample run, weigh the sample
of product using the scales supplied with the
seeder.
NOTE: It is the responsibility of the
operator to check the accuracy of the
scales on a regular basis.
Page 2
Calibration Speed Settings (
Default setting 4
)
Low application rates
2kg/ha
– 4 kg/ha
2-3
Medium application rates
4kg/ha
–10 kg/ha
4
High application rates
10kg - above
5-7
TABLE. 30
Summary of Contents for Pasture Planter
Page 2: ...Page Intentionally Blank ...
Page 4: ...06 14 Page Intentionally Blank ...
Page 9: ...SPARE PARTS RECORD Page 5 10 09 PART No DESCRIPTION QTY COST DATE ...
Page 10: ...Page Intentionally Blank ...
Page 30: ...06 14 Page Intentionally Blank ...
Page 31: ...10 09 SPARE PARTS ...
Page 32: ...P Planter Common Parts Page 28 10 09 ...
Page 34: ...P Planter Meterbox Page 30 06 14 ...
Page 38: ...P Planter 600L Bin Assembly Page 34 06 14 AS USED ON 1890 2120 2150 MODELS POST NOV 2011 ...
Page 40: ...P Planter 600L Bin Assembly Page 36 06 14 AS USED ON 1860 MODELS POST NOV 2011 ...
Page 42: ...P Planter Adjustment Assembly Page 38 06 14 ...
Page 54: ...Mount Kit 1850FT 380L Page 50 10 09 ...
Page 56: ...Mount Kit 1860RT 600L Page 52 06 14 Post Nov 2011 ...
Page 58: ...Mount Kit 1860FT 600L Page 54 06 14 Post Nov 2011 ...
Page 60: ...Mount Kit 1860RT FT 380L Page 56 10 09 Pre Nov 2011 ...
Page 62: ...Mount Kit 1890RT CTS 600L Page 58 06 14 Post Nov 2011 ...
Page 80: ...Mount Kit 2120 50 LQ 600L Page 76 06 14 Post Nov 2011 ...
Page 106: ...Instruction Detail VRT Hyd Drive Components 1860 2150 Page 102 06 14 ...