PASTURE PLANTER METERBOX - ADJUSTMENTS
Page
13
10/09
Fitment of Reducer Plate
To achieve very low rates with small seeds
a reducer plate is fitted to the Pasture Planter
meterbox. This reduces the meterwheels output
to approximately 1/3. The following steps are for
fitment of the reducer plate, removal is a reversal
of this procedure.
Step 1. Remove window assembly.
Fig.12 Removal of window assembly
Step 2. Fit reducing plate onto bolt inside the
meterbox.
Fig.13 Fit reducing plate.
Step 3. Fit wing nut and tighten and then refit
window assembly.
Fig.14 Wing nut securing reducer plate.
Caution: Only use with very small seeds such as
Canola, Medics (clover seed) or Sorghum.
Always re-calibrate Pasture Planter after
fitting or removing the reducer plate.
Summary of Contents for Pasture Planter
Page 2: ...Page Intentionally Blank ...
Page 4: ...06 14 Page Intentionally Blank ...
Page 9: ...SPARE PARTS RECORD Page 5 10 09 PART No DESCRIPTION QTY COST DATE ...
Page 10: ...Page Intentionally Blank ...
Page 30: ...06 14 Page Intentionally Blank ...
Page 31: ...10 09 SPARE PARTS ...
Page 32: ...P Planter Common Parts Page 28 10 09 ...
Page 34: ...P Planter Meterbox Page 30 06 14 ...
Page 38: ...P Planter 600L Bin Assembly Page 34 06 14 AS USED ON 1890 2120 2150 MODELS POST NOV 2011 ...
Page 40: ...P Planter 600L Bin Assembly Page 36 06 14 AS USED ON 1860 MODELS POST NOV 2011 ...
Page 42: ...P Planter Adjustment Assembly Page 38 06 14 ...
Page 54: ...Mount Kit 1850FT 380L Page 50 10 09 ...
Page 56: ...Mount Kit 1860RT 600L Page 52 06 14 Post Nov 2011 ...
Page 58: ...Mount Kit 1860FT 600L Page 54 06 14 Post Nov 2011 ...
Page 60: ...Mount Kit 1860RT FT 380L Page 56 10 09 Pre Nov 2011 ...
Page 62: ...Mount Kit 1890RT CTS 600L Page 58 06 14 Post Nov 2011 ...
Page 80: ...Mount Kit 2120 50 LQ 600L Page 76 06 14 Post Nov 2011 ...
Page 106: ...Instruction Detail VRT Hyd Drive Components 1860 2150 Page 102 06 14 ...