![Gasboy Islander PLUS Installation Manual Download Page 17](http://html1.mh-extra.com/html/gasboy/islander-plus/islander-plus_installation-manual_3660001017.webp)
1-3.
SYSTEM OVERVIEW
1-3.1. Islander PLUS System
Islander PLUS is an innovative product that enables refueling in Home Base stations for fleets
authorized vehicles or drivers. Islander PLUS electronically locks all dispensers and pumps thereby
ensuring that only appropriately authorized vehicles and plants receive the required fuel. The
system also ensures accurate recording of each transaction (see Figure 1-2).
The heart of the Home Base Station solution is the SiteOmat automation software. SiteOmat runs
on an embedded operating system on the OrCU (Orpak Controller Unit). OrCU is an embedded
hardware platform designed to survive the harsh gas station environment. It uses a solid state Flash
disk and RTC (Real Time Clock) with back-up, along with surge suppressors for transient and noise
immunity. The system also includes power fail recovery mechanisms.
1-3.2. Vehicle Identification – FuelPoint PLUS
Vehicle Identification is an important option for maximal control and savings on fuel expenditure.
The dispenser is authorized to refuel after a positive identification of the vehicle and only while the
nozzle is inside the fuel inlet of the identified vehicle. All transaction information is automatically
recorded. A combined vehicle and driver identification is also possible for tight tracking.
1-3.3. Remote Web Access
Remote Web-based capabilities for monitoring, management and maintenance are available. A
standard PC with Internet Browser (Explorer) is used for management of the site either locally or
remotely (secured). There is no need for special management software; thanks to the built-in Web
server technology integrated into the station controller and a large variety of communication links is
supported – both wired and wireless.
1-3.4. Head Office
Centralized management is provided by the optional Fleet and Fuel Head Office server. The Fleet
and fuel Head Office consolidates the data from multiple sites and generates reports, including
exception reports. It also enables control of the limits and restrictions placed on the various fleet
vehicles. Furthermore, authorized fleet personnel are able to log-in remotely and are always in
control. Head office enables authorized users to control and manage wet stock inventory on all
stations including orders, deliveries and reports.
1-3.5. Restrictions and Limits
Control of a fleet’s fuel expenses can be maximized by defining limits (day, week, month),
maximum number of refueling (day, week, month) and setting restrictions (days of the week, fuel
type, stations, time intervals). In case of system configuration for multiple sites, the centralized
Fleet Head Office needs to synchronize the data between all sites so that the limits can be applied to
a whole system rather than to an individual site. In case of communication failure, the specific site
will be able to refuel for a predefined grace period (parameter) using the most recent limits stored in
its database.
Islander PLUS Manual
3
Summary of Contents for Islander PLUS
Page 4: ...This document is the property of ORPAK SYSTEMS Ltd ISRAEL ...
Page 10: ...TABLE OF CONTENTS Paragraph Page INSTALLATION INSTRUCTIONS 127 Islander PLUS Manual vi ...
Page 14: ......
Page 16: ...Figure 1 1 Islander PLUS ICR PLUS General View Islander PLUS Manual 2 ...
Page 26: ...Figure 1 6 Internal Components Location 8 Mechanical Pumps Islander PLUS Manual 12 ...
Page 29: ......
Page 35: ...Figure 1 10 Islander PLUS ICR PLUS Dimensions Islander PLUS Manual 21 ...
Page 41: ......
Page 48: ...Figure 2 4 Conduits Layout for Mechanical Pump Islander PLUS Manual 34 ...
Page 49: ...Figure 2 5 Conduits Layout for Electronic Pump Islander PLUS Manual 35 ...
Page 60: ...Figure 3 2 Home Base Station with 4 Mechanical Pumps System Diagram Islander PLUS Manual 46 ...
Page 61: ...Figure 3 3 Home Base Station with 8 Mechanical Pumps System Diagram Islander PLUS Manual 47 ...
Page 62: ...Figure 3 4 Home Base Station with Electronic Pumps System Diagram Islander PLUS Manual 48 ...
Page 65: ...Figure 3 5 Islander PLUS Terminal Block Power and LAN Connections Islander PLUS Manual 51 ...
Page 81: ...Figure 3 18 Mechanical Pump Single Dispenser Connections Islander PLUS Manual 67 ...
Page 82: ...Figure 3 19 Mechanical Pump Twin Dispenser Connections Islander PLUS Manual 68 ...
Page 87: ...Figure 3 23 Islander PLUS Terminal Block Wiring List Label Islander PLUS Manual 73 ...
Page 93: ...Figure 3 29 Journal Printer Rear Panel Islander PLUS Manual 79 ...
Page 134: ...Islander PLUS Manual 120 ...
Page 136: ...Figure B 1 Islander PLUS Wiring Diagram Mechanical Pump Islander PLUS Manual 122 ...
Page 137: ...Figure B 2 Islander PLUS Wiring Diagram Electronic Pump Islander PLUS Manual 123 ...
Page 138: ...Figure B 3 Islander PLUS for 8 hoses Wiring Diagram Islander PLUS Manual 124 ...
Page 140: ...Figure 1 HID Unit and Connector Figure 2 HID Holder and Nuts Islander PLUS Manual 126 ...
Page 146: ...Figure 11 Placing Hand Tag Label on Pedestal Islander PLUS Manual 132 ...