Installing New Atlas Motor Kits

  

Installing New Atlas Motor Kits

Preparing for the Installation

1

Request permission from the manager/owner to remove power from the unit and then remove 

power using normal procedures. Perform the lockout/tagout safety procedures.

2

Ensure that you have the proper kit for the model unit to be retrofitted.

3

Follow all applicable safety rules and procedures.

Installing the New Atlas Motor

To install the new Atlas motor, remove the old motor and then install the new one, as 
explained below:

Removing the Old Motor

1

Disconnect motor wires in the junction box. Mark wires in junction box so that you can be sure 

of connecting the new motor correctly.

2

Remove the belt.

3

Disconnect motor conduit at the expansion union. Refer to 

Figure 1

.

4

Remove the two shoulder bolts on the bottom of the motor deck plate. Remove the washers, 

cupped washers and rubber mounts. Refer to 

Figure 2

. Retain all hardware.

5

While place something underneath the motor to prevent it from dropping suddenly, remove the 

two flanged screws from the top of the motor deck plate, and retain the hardware.

6

Remove the motor from the unit.

7

Remove the motor from the motor deck plate and retain the hardware.

Figure 1: Old Atlas Motor

 

Flanged screws 
at top of Motor 
Deck Plate

Motor Deck 
Plate

Motor Deck 
Plate

Expansion   
Union

Summary of Contents for Atlas M06699K Series

Page 1: ...99K002 Atlas Motor Kit 1 HP 50HZ 1PH Required Reading Before installing a kit the installer must read understand and follow This manual NFPA 30A The Automotive and Marine Service Station Code NFPA 70...

Page 2: ...99K001 Part Number Description Quantity per Kit R14213 32 Motor 1 HP 60 Hz 1 PH 1 R06711 52 V Belt 4L290 1 R18900 27 Pulley A Belt 2 50 PD 1 Atlas Motor Parts List for M06699K002 Part Number Descripti...

Page 3: ...ual Read understand and follow this manual and any other labels or related materials supplied with this equipment If you do not understand a procedure call a Gasboy Authorized Service Contractor or ca...

Page 4: ...handling equipment Do not place any equipment in mouth This area contains a chemical known to the State of California to cause cancer WARNING This area contains a chemical known to the State of Califo...

Page 5: ...oving the Old Motor 1 Disconnect motor wires in the junction box Mark wires in junction box so that you can be sure of connecting the new motor correctly 2 Remove the belt 3 Disconnect motor conduit a...

Page 6: ...te flange 6 Replace the rubber mounts cupped washers and washers and the shoulder bolts in the slots on the bottom of the deck plate and thread the shoulder bolts into the clinch nuts in the bottom fr...

Page 7: ...r Adjust if necessary Refer to Figure 3 Figure 3 Atlas Pump Motor Select Switch Motor power select switch shown in low voltage setting 110 volt nominal Verifying Performance 1 Verify completion of the...

Page 8: ...s Screw 2 If the amperage from the initial test is low turn the adjustment screw clockwise and increase the preload and thus the flowrate and motor load Note If the initial bypass voltage is below 205...