MDE-4567D 9820K Series AST Pumps Installation and Operation Manual · January 2020
Page 1
Purpose
Introduction
1 – Introduction
Purpose
The purpose of this manual is to assist Gasboy
®
Authorized Service Contractors (ASCs) in
installing and operating the 9820K Electronic Commercial pump unit used with Aboveground
Storage Tanks (ASTs).
Note: Whenever information in this document applies to the unit mentioned above, the 9820K
model reference is used. 9120K Compact Mechanical Commercial pump is no longer
available.
General Description
Model 9820K
The Gasboy Series 9820K Aboveground Storage Tank Remote Access (ASTRA
®
) pump units
are UL
®
-listed.
Note: NFPA regulations do not allow tank-mounted pumps to be used for the resale of fuel.
The 9820K Series units consist of two metal cabinet assemblies.
• One assembly is mounted on top of the tank and contains the pumping unit, meter,
electronic pulser, and all hydraulics. The hose and nozzle are connected to this assembly.
• The second assembly is mounted at a height to permit easy access by a user. It contains the
electronic register, controls, display and nozzle boot.
The standard features and specifications of the 9820K Series pumps are as follows:
• One-inch high, 6-digit, backlighted Liquid Crystal Display (LCD)
• 1000:1 dual-phase, error-checking pulser (gallons); 250:1 dual-phase, error-checking
pulser (liters)
• AC authorization line for control of the unit
• Reset complete (Switch Detect) output that allows monitoring of the unit's operation when
it is connected to an automated fueling system
• Resettable electronic totalizer
• Discharge elbow
• This model uses a quiet and efficient pump which features an air eliminator built into the
pump casting. The pump meter is a four-piston, positive displacement meter which is
tested and calibrated for accuracy at any speed or pressure up to the maximum working
pressure of 50 psi.
• The standard pumping cabinet finish is white. The electronic register cabinet is black with
a blue graphics panel
• Dual Stage Solenoid Valve
• Filter
• Ability to display last transaction and capture of stored pulse count in the event of a power
failure