-
16
-
3. Disconnect the terminals ensuring that they do not
enter into contact with metal parts then extract the
battery.
WARNING
Hydrogen gas produced by the battery may explode if exposed to
open flame or sparks.
Keep the area ventilated and free from naked flames.
The operating instructions for the battery are as follows:
1.
Check the battery tension in open circuit status (disconnected).
2.
In case the battery's tension is below 12.60 V, or if the storage
period has exceeded 6 months, the battery has to be recharged
following the instructions in paragraph 3.
If the battery voltage is above 12.60 V, the battery can be
installed on the vehicle without having to recharge it.
3.1. Constant voltage charge mode.
- Constant voltage = 14.40 - 14.70V
- Initial charge current = 0.1 – 0.5 Cn
- Charge duration = 6 hours minimum / 24 hours maximum.
3.2. Constant power charge mode.
- Maximum charge current = 0.1 Cn
(A)
(C)
(B)
BATTERY
This battery is maintenance free and checking the fluid level is not
required. It is advisable to check the charge of the battery periodically
To remove the battery, follow these steps:
1. Remove the bolt (A) and remove the seat (B).
2. Release the rubber (C).