6
©2003 GARRETT METAL DETECTORS
PN 1532010 REV A
1.1
TECHNICAL SPECIFICATIONS
1.1.1 DIMENSIONS
• Passage Interior: Width: 30" (0.76m) Height: 80" (2m)
Depth: 23" (0.58m)
• Overall Exterior: Width: 35" (0.9m) Height: 87" (2.2m) Depth: 23" (0.58m)
• Shipping:
Width: 35.5" (0.9m)Height: 92" (2.3m) Depth: 6.5"(0.17m)
Shipping Weight: 165 lbs (74 kg)
1.1.2 OPERATING
CONDITIONS
Temperature:
-4ºF (-20ºC) to +158ºF (70ºC)
Humidity:
Up to 95% non-condensing.
1.2 REGULATORY INFORMATION
The PD 6500
i
meets or exceeds all industry safety and electromagnetic
compatibility (EMC) standards and conforms to international directives
(CE approved).
Garrett research has produced no information which would indicate that
Garrett products would have any adverse effects on medical implants,
pregnancy, recording media or magnetic strips. Garrett consistently
cooperates with medical device manufacturers and communicates with
agencies such as the United States FDA (Food and Drug Administration) and
Health Canada to continue the assurance of Garrett products’ safety. Any
recommendations or directives issued by personal physicians should be
followed. If, for any reason (e.g., doctor’s orders, etc.), a patron objects to
being scanned with a metal detector, it is recommended that an alternative
procedure (e.g., "hand wanding", "pat down", non-admittance, etc.) be a part
of the overall security plan.
The PD 6500
i
is made of scratch and mar resistant laminate with resilient
end caps, a control panel and heavy-duty aluminum crosspiece. Smooth
rounded corner design ensures no puncturing, cutting or tearing of the skin
or clothing or otherwise causing bodily injury. A key lock panel protects critical
circuitry, wires, cables, data cables and power connectors to prevent
tampering or injury.
1.2.1
ELECTRICAL SAFETY
The Garrett PD 6500
i
has been tested and found to comply with:
• Canadian Standard - CAN / CSA-C22.2 No. 1010.1 and CAN / CSA-
C22.2 No. 1010.1B-97 Safety Requirements for Measurement, Control
and Laboratory Use, Part 1: General Requirements.
• United States Standard - UL 3101-1 1993 Electrical Equipment for
Laboratory Use, Part 1: General Requirements.
GARRETT PD 6500
i
USER MANUAL