Technical data
Specifications
Product type:
all GLB models
Standards/directives:
IEC 61851-1 and IEC TS 61439-7
Installation:
on wall
Voltage rating:
230V/400 50Hz
Installation systems:
TT, TN and IT systems
Charging type:
Mode 3
IP classification:
IP44
Mechanical impact
resistance:
IK08
Application temperature:
-25
0
C – +40
0
C (without direct sunlight)
Storage temperature:
-35
0
C – +55
0
C
Installation height:
0.5–1.5 metres above ground/land to lower edge of
charger
Weight:
around 3 kg including socket outlet
3.8–4.1 kg including cable and connector, 1-phase
5.4 kg including cable and connector, 3-phase
Cable length:
5 m (Only GLB models with fixed cables)