30
31
EN
EN
H
A
(figure 17)
End user instrucion /
Resetting/Conditioning of RCCB or RCBO
If the wallbox is equipped with a RCCB or RCBO (H). In the event of overload/earth
fault, these can be tripped. These components must also be conditioned every 6 months.
Procedure for resetting/conditioning:
1. Disconnect the car.
2. Unlock the front cover with the key provided.
3. Open the front cover (A) by sliding it downwards.
4. Reset the circuit breaker. When conditioning press the test button, then reset the
circuit breaker.
5. Close the front cover by sliding it upwards.
6. Lock the front cover with the key.
Resetting/Conditioning of RCCB or RCBO
Do not modify the equipment installation or any part of the product.
Do not touch the GLB+ Wallbox’s end terminals with fingers or any other objects.
Do not insert foreign objects into any part of the GLB+ Wallbox.
Incorrect installation and testing of the GLB+ Wallbox could potentially damage
either the vehicle’s Battery and/or the GLB+ Wallbox itself.
End user instrucion /
Resetting/Conditioning of RCCB or RCBO
The front cover must always be locked in its upper position in order to ensure
compliance with IP Code IP44.