E F A P O W E R E V - Q C 4 5 S T A N D A L O N E - I N S T A L L A T I O N A N D U S E R M A N U A L
13/32
For the power cabinet, the conduits must extend 160mm (6.3”) above the concrete, or according to local
codes. The
cable entrance shall only be located as show n in the image below
(marked in green).
The access to all the controls and
commands including the buttons and the card reader
, must comply with local
codes and
ADA req uirements
. That includes being
under 1200mm
(
48”
) off the ground.
Figure 9 - EFAPOWER EV-QC45 Drilling and conduits layout
(bottom view)
IMPORTANT:
The use of chemical anchors must be in compliance with the manufacturer’s instructions
For the Power Cabinet it’s advised to have a concrete block of at least 800mm (31.5”) square, by 254mm
(10”) deep. Check local codes to ensure compliance
The bolts must extend at least 30.5mm (1.2”) above the concrete and 89.5mm (3.52”) into the concrete
ALL SERVICING MUST BE PERFORMED ONLY BY QUALIFIED PERSONNEL. DO NOT
ATTEMPT TO SERVICE THE EFAPOWER EV QC45 QUICK CHARGING STATION
YOURSELF.
BY OPENING THE DOOR OR REMOVING THE EFAPOWER EV QC45 QUICK
CHARGING STATION SIDE PANELS YOU RUN THE RISK OF EXPOSURE TO
DANGEROUS VOLTAGES!