24
EN
H
A
If the GLB Wallbox is equipped with a RCCB or RCBO (H) (figure
24). In the event of overload/earth fault, these can be tripped.
These components must also be conditioned every 6 months.
Procedure for resetting/conditioning:
1. Disconnect the car.
2. Unlock the front cover with the key provided.
3. Open the front cover (A) (figure 24) by sliding it downwards.
4. Reset the circuit breaker. When conditioning press the test
button, then reset the circuit breaker.
5. Close the front cover by sliding it upwards.
6. Lock the front cover with the key.
The front cover must always be locked in its upper position in
order to ensure compliance with IP Code IP44.
Resetting/Conditioning of RCCB or RCBO
(figure 24)
User instructions