background image

INSTALLATION OF ACCESSORIES

Two Castra campingstations can be installed “back to back” pic 6. 
(use GARO art no 353918)

Water taps installation, pic 7 (GARO art no 352711) 
 

Basic LED indications

Solid green light: ready for charging

Flashing green light: Castra waiting for start 
signal from electric vehicle. 

Shifting blue light intensity: charging

Other LED indicatoions: see User manual at  
www.garoemobility.com/support

Error codes:

Fixed yellow light: reconnect the charging cable.

Fixed white light: EV outlets not activated, contact 
serviceperson.

No light: Contact service person

Fixed red light: Reset RCBO 

Slow red blink: Modbus problem with energymeters, 
contact service person

Red blink: RFID tag not valid

4

EN

USER INSTRUCTIONS

Connect the charging cable to the EV outlet.

If RFID authorization is activated, hold a valid RFID-tag in front of 
the RFID-reader at same side as the charging cable in use.

The charging process is activated if the EV is ready for charging. 
See your EV manual.

When charging is complete, follow the instruction in your EV 
manual.

INSTALLATION 

1. Open the front door and remove the protection cover.

2. Cut a round hole in the gasket for the incoming cable. Make 
sure the gasket fits tight around the cable to prevent dirt, dust and 
bugs to enter the top housing part.

3. Install Castra on a pole dia 60mm or on a ground foundation 
pic2. Pole or ground foundation is not included.

4. Install the incoming cable, pic 3 and 4. 
Note: 3-wire system, add a jumper between L1 and L2 on the 
terminal block.

When several Castra campingstations are connected to same 
distribution board, phase-rotation is recommended to even out the 
load between the phases.

Example:
1st Castra: L1, L2, L3
2nd Castra: L3, L1, L3
3rd Castra: L2, L3, L1

And so on…

5. Fix the protection cover.

6. Turn on the power and wait a few minutes for Castra to start up 
properly.

7. Test Castra both side outlets with a test instrument.

8. Fill in the warranty form, sign with name, date and company 
name in order for the warranty to be valid. Give the signed 
warranty form to the owner of the site.

Summary of Contents for Castra CLS1

Page 1: ...GARO AB GARO Castra Box 203 SE 335 25 Gnosj Phone 46 0 370 33 28 00 info garo se garo se Manual 380238 Installation manual...

Page 2: ...e 3 INSTALLATION 4 INSTALLATION OF ACCESSORIES 4 USER INSTRUCTIONS 4 Technical date 5 Software update 5 Service Maintenance 5 Troubleshooting Support 5 GARANTIVILLKOR WARRANTY CONDITIONS 11 WARRANTY F...

Page 3: ...nsumption kWh for each side of Castra Both 216 6 and EV outlets are individually protected to RCBO s Both EV outlets have individual DC fault monitoring devices Castra campingstation are delivered wit...

Page 4: ...ted if the EV is ready for charging See your EV manual When charging is complete follow the instruction in your EV manual INSTALLATION 1 Open the front door and remove the protection cover 2 Cut a rou...

Page 5: ...ation type Non restricted Access Charging method AC Charging Rated current withstand 10kA Rated short time withstand current 10kA Rated conditional short circuit current of an assembly 10kA Short circ...

Page 6: ...476 10 mm 1 2 pole 2 ground Option Art no 352699 E2449896 6 EN...

Page 7: ...3 4 5 a b 7 EN...

Page 8: ...Option Art no 352711 E2449844 Option Art no 353918 40 5 mm 0 5 x8 x4 x4 x4 8 EN...

Page 9: ...1 PP 2 CP 2 Red White PP 1 CP 1 Red White LINE L FC2 FC1 XN1 XPE1 QA1 QA2 A B XPE1 XN1 H GER SIDA V NSTER SIDA N N 1 2 B A 6 7 8 5 P2 RS 485 N N 1 2 B A 6 7 8 5 P1 RS 485 N 2 FC2 C10A N 1 mA 30 N 2 FC...

Page 10: ...C2 XN1 XPE1 QA1 QA2 LINE L A B P2 communication cable communication cable KF1 Connector for Led light Topcard Connector for the RFID reader Connector for Led light Topcard Connector for the RFID reade...

Page 11: ...number 7 Warranty does not cover damage occured by incorrect use of equipment use of any nonoriginal spareparts lack of maintenence or faults caused by disassembly of the product or unauthorized perso...

Page 12: ...ICAL INSTALLATION DATA Group fuse A Grupps kring A Supply cable dimension Kabelarea FUNCTION TEST Testbox EV model Date Datum Sign Installer Sign installat r Company Name F retagsnamn Owner Customer N...

Page 13: ...GARO AB Box 203 SE 335 25 Gnosj Phone 46 0 370 33 28 00 info garo se garo se...

Reviews: