Placement of the main unit

 

Select the location of the main unit that is free from direct sunlight. Test the connection to the wireless 
sensor before final installation. If there is a problem with the signal reception, select another location. There 
is a mounting hole for suspension on the rear of the main unit. Use the part to suspend the main unit You 
may also put the main unit on a flat surface. 
 
 

TIME AND DATE CONTROLED BY THE DCF-77 RADIO SIGNAL 

 
The wireless sensor is equipped with a DCF-77 signal receiver for time and date adjustment, so it is 
suitable to place the wireless sensor outdoors for better reception. The DCF-77 is broadcast by a 
transmitter from Frankfurt am Main, Germany, with a range of about 1500 km. The time and date is 
adjusted every day.  In case of poor reception conditions time and date can be adjusted manually.  
 
After time and date have been adjusted manually, they will be readjusted upon reception of the DCF-77 
signal. 
 
When the batteries are inserted into the main unit and the wireless sensor and the connection is 
established, the wireless sensor will start to receive the DCF-77 signal. If the signal is not received, the 
DCF-77 signal reception icon will not be shown on the display. Upon successful reception the reception 

icon 

  will be displayed on the display, if the signal is not received, the icon 

 will be displayed

 

 
The DCF-77 signal is automatically scanned for every day between 10pm and 5pm, when the interference 
is at the lowest. 

 

Note: The DCF-77 signal receiver for time and date adjustment is integrated into the wireless sensor, 
          so the wireless sensor should be positioned to ensure good reception of the DCF-77 signal,  
          that is outdoors, away from potential sources of interference. Receiving and adjusting time can  
          take up to 10 minutes. 
 
MEMORY FOR MAX AND MIN MEASURED VALUES 

 

The main unit is equipped with memory for maximum and minimum measured values

Press the 

- / MEM

 

button repeatedly to display the maximum and minimum measured values of the indoor and outdoor 
temperature and relative humidity. MAX or MIN is displayed above the time. Press and hold the 

- / MEM 

button for 3 seconds; a beep will sound and the memory will be erased. 
 

MEMORY OF MEASURED VALUES FOR THE LAST 24 HOURS 

 

Press and hold the 

DEW / HEAT 

button for 3 seconds to display the measured values of the indoor and 

outdoor temperature and relative humidity.

 

A beep will sound and hour will be displayed at the time spot. 

Use the 

- / MEM

 and 

+ / CH 

buttons to display the values stored for every hour. 

 

HEAT INDEX / DEW POINT 

 

Press the 

DEW / HEAT 

button repeatedly to display the outdoor heat Index 

– subjective temperature 

(HEAT INDEX) and the outdoor dew point (DEW POINT), which is indicated by labels next to the display of 
the barometric pressure. 

The temperature index value (HEAT INDEX) is displayed from 26°C outdoor 

temperature and 40% outdoor relative humidity. For lower readings, the temperature index value is 
irrelevant and “Lo” is displayed. 

 

ALARM CLOCK 

 

Setting of alarm time 

 

The weather station allows setting of the wake-up time. In the basic display mode, press and hold the 
ALARM button for 3 seconds. A beep will sound. The alarm time will be displayed at the time spot and the 
hour will flash. Use the 

- / MEM

 and 

+ / CH 

buttons to set the required wake-up hour and press 

ALARM 

shortly. Minutes will flash. Use the 

- / MEM

 and 

+ / CH

 buttons to set the required wake-up minute. After 

another press, a beep will sound and the setting will be saved. 
 

Summary of Contents for GARNI610 Precise

Page 1: ...INSTRUCTION MANUAL FOR WEATHER STATION MODEL Precise Precise ...

Page 2: ...its of indoor and outdoor temperature weather forecast icons based on monitoring of changes in barometric pressure option to set a default weather forecast icon absolute relative barometric pressure display display of outdoor heat Index and dew point memory for maximum and minimum measured values of temperature and rel humidity memory for measured values of temperature rel humidity and barometric ...

Page 3: ...imits of the outdoor temperature 5 Indoor temperature and relative humidity alarm upper and lower limits of the indoor temperature Rear side of the main unit 6 Mounting hole 7 Power adapter socket 8 Battery compartment cover 9 Acoustic alarm opening Wireless sensor GARNI 060H 10 TX button 11 Battery compartment cover 12 Battery compartment ...

Page 4: ...Year will flash Use the MEM and CH buttons to set the current year and confirm with SET 7 Month will flash Use the MEM and CH buttons to set the current month and confirm with SET 8 Day will flash Use the MEM and CH buttons to set the current day and confirm with SET 9 The day name shortcut will flash Use the MEM and CH buttons to set the required language CZ Czech EN English DE German IT Italian ...

Page 5: ...lash Now press the TX button in the battery compartment of the wireless sensor Select a different channel for each wireless sensor Once the connection of the main unit to the wireless sensor is established the icon will be displayed permanently Place the main unit and the wireless sensor in the desired location within the range of the wireless sensor signal The connection establishment process mus...

Page 6: ...ioned to ensure good reception of the DCF 77 signal that is outdoors away from potential sources of interference Receiving and adjusting time can take up to 10 minutes MEMORY FOR MAX AND MIN MEASURED VALUES The main unit is equipped with memory for maximum and minimum measured values Press the MEM button repeatedly to display the maximum and minimum measured values of the indoor and outdoor temper...

Page 7: ...ash Use the MEM and CH buttons to set the required temperature The temperature alarm is enabled or disabled by pressing the ALARM button The activation of the alarm is indicated on the display by the icon The upper limit alarm for the indoor temperature can be set from 9 C to 60 C the lower limit from 10 C to 59 C The upper limit alarm for the outdoor temperature can be set from 9 C to 70 C the lo...

Page 8: ...reless sensor away from other electrical equipment the main unit keeps displaying the outdoor temperature and rel humidity even after the wireless sensor is disconnected the main unit displays the last measured data for 30 minutes after disconnection of the wireless sensor the temperature and rel humidity are different when the main unit and the wireless sensor are placed next to each other measur...

Page 9: ...ature measurement range 10 C to 60 C Measurement accuracy 0 2 C 10 C to 50 C Resolution 0 1 C Humidity measurement range 1 to 99 Accuracy of measurement 2 20 to 80 4 1 to 20 80 to 99 Resolution 1 Outdoor HEAT INDEX from 26 C from 40 relative humidity Type of used sensors SENSIRION SHTC3 Dimensions 194 9 x 130 8 x 35 7 mm Wireless sensor GARNI 060H Power supply 2 pcs batteries type AAA 1 5 V micro ...

Reviews: