Enabling the alarm clock 

 

In the basic display mode, press and hold the 

ALARM

 button.  One press enables the alarm clock, two 

presses disable it. The display indicates the enabled alarm clock with the icon 

 

 
Turning off alarm signal, Snooze 

 

As soon as the alarm signal goes off at the preset time, you can activate the Snooze function by pressing 

SNOOZE / LIGHT

. The icon   

 will flash one the display. The alarm signal will be reactivated  

after 5 minutes. 
If you do not want the Snooze function, press the 

ALARM 

button to disable the alarm signal. 

If no button is pressed, the alarm signal will be turned off automatically after 2 minutes. 

 

SETTING OF ALARM FOR THE UPPER AND LOWER TEMPERATURE LIMIT 

 

The weather station allows setting the alarm of the upper and lower limits of indoor and outdoor 
temperature. In the basic display mode, press and hold the 

ALERT

 button.  

 

1 x press 

displays the upper limit (HIGH) of the indoor temperature (INDOOR TEMPERATURE) 

2 x press 

displays the lower limit (LOW) of the indoor temperature (INDOOR TEMPERATURE) 

3 x press 

displays the upper limit (HIGH) of the outdoor temperature (OUTDOOR TEMPERATURE) 

4 x press 

displays the lower limit (LOW) of the outdoor temperature (OUTDOOR TEMPERATURE) 

5 x press 

basic display mode 

 

Choose which value to set and press and hold the 

ALERT

 button for 3 seconds. A beep will sound and the 

temperature will flash. Use the 

- / MEM

 and 

+ / CH 

buttons to set the required temperature. 

The temperature alarm is enabled (or disabled) by pressing the 

ALARM

 button. The activation of the alarm 

is indicated on the display by the icon 

 

The upper limit alarm for the indoor temperature can be set from -

9° C to + 60° C, the lower limit from -10° 

C to + 59° C 
The upper limit alarm for the outdoor temperature can be set from -

9° C to + 70° C, the lower limit from -40° 

C to + 

59° C 

 

Activating the alarm for the upper and lower temperature limit 

 

Exceeding the set temperature limit will be indicated by an acoustic signal at regular intervals, the 
corresponding 

HIGH

 or 

LOW

 icon will flash on the display.   

To disable the alarm perform the same procedure as for its setting, deactivate the alarm by pressing 

ALARM

, the icon 

 will not be displayed.

 

 

Note:  if multiple wireless sensors are used, the upper and lower temperature limit alarm can be se for  
          each sensor separately. Select the sensor with the + / CH button 

 

WEATHER FORECAST 

 

The forecast is based on the change in barometric pressure, generally speaking when the barometric 
pressure rises, the weather improves and vice versa. The weather forecast is valid for the next 12 to 24 
hours within 30 to 50 km with the probability of 70 to 75%.

 

The weather forecast is displayed using 5 icons  

 

   clear                  somewhat cloudy                   cloudy                        precipitation                    stormy 

 
After switching on the station, it is necessary to wait for at least 24 hours to display the correct 
weather forecast. To speed up the process, the default weather forecast icon can be set according 
to the current situation.  

Summary of Contents for GARNI610 Precise

Page 1: ...INSTRUCTION MANUAL FOR WEATHER STATION MODEL Precise Precise ...

Page 2: ...its of indoor and outdoor temperature weather forecast icons based on monitoring of changes in barometric pressure option to set a default weather forecast icon absolute relative barometric pressure display display of outdoor heat Index and dew point memory for maximum and minimum measured values of temperature and rel humidity memory for measured values of temperature rel humidity and barometric ...

Page 3: ...imits of the outdoor temperature 5 Indoor temperature and relative humidity alarm upper and lower limits of the indoor temperature Rear side of the main unit 6 Mounting hole 7 Power adapter socket 8 Battery compartment cover 9 Acoustic alarm opening Wireless sensor GARNI 060H 10 TX button 11 Battery compartment cover 12 Battery compartment ...

Page 4: ...Year will flash Use the MEM and CH buttons to set the current year and confirm with SET 7 Month will flash Use the MEM and CH buttons to set the current month and confirm with SET 8 Day will flash Use the MEM and CH buttons to set the current day and confirm with SET 9 The day name shortcut will flash Use the MEM and CH buttons to set the required language CZ Czech EN English DE German IT Italian ...

Page 5: ...lash Now press the TX button in the battery compartment of the wireless sensor Select a different channel for each wireless sensor Once the connection of the main unit to the wireless sensor is established the icon will be displayed permanently Place the main unit and the wireless sensor in the desired location within the range of the wireless sensor signal The connection establishment process mus...

Page 6: ...ioned to ensure good reception of the DCF 77 signal that is outdoors away from potential sources of interference Receiving and adjusting time can take up to 10 minutes MEMORY FOR MAX AND MIN MEASURED VALUES The main unit is equipped with memory for maximum and minimum measured values Press the MEM button repeatedly to display the maximum and minimum measured values of the indoor and outdoor temper...

Page 7: ...ash Use the MEM and CH buttons to set the required temperature The temperature alarm is enabled or disabled by pressing the ALARM button The activation of the alarm is indicated on the display by the icon The upper limit alarm for the indoor temperature can be set from 9 C to 60 C the lower limit from 10 C to 59 C The upper limit alarm for the outdoor temperature can be set from 9 C to 70 C the lo...

Page 8: ...reless sensor away from other electrical equipment the main unit keeps displaying the outdoor temperature and rel humidity even after the wireless sensor is disconnected the main unit displays the last measured data for 30 minutes after disconnection of the wireless sensor the temperature and rel humidity are different when the main unit and the wireless sensor are placed next to each other measur...

Page 9: ...ature measurement range 10 C to 60 C Measurement accuracy 0 2 C 10 C to 50 C Resolution 0 1 C Humidity measurement range 1 to 99 Accuracy of measurement 2 20 to 80 4 1 to 20 80 to 99 Resolution 1 Outdoor HEAT INDEX from 26 C from 40 relative humidity Type of used sensors SENSIRION SHTC3 Dimensions 194 9 x 130 8 x 35 7 mm Wireless sensor GARNI 060H Power supply 2 pcs batteries type AAA 1 5 V micro ...

Reviews: