Page 24
810-PS2 Manual
the tank, and off at the bottom). The shut down mode turns
the alarm off as the tank level rises past the alarm point (i.e.,
the alarm is on at the bottom of the tank, and off at the top).
6. If the automatic alarm (the purple wire) is to be used, program
Alarm 4 as shut down at the point where the horn is to
come on, and program Alarm 3 as shut down a few inches
above where the float will sit at the bottom of the tank. The
automatic alarm is a special output so that even though Alarm
4 is programmed as shut down, the horn will be turned on
when the level rises above the Alarm 4 point, and then will
turn off when the alarm is silenced. When the fluid level goes
below the Alarm 3 point, the alarm will be re-armed so it will
sound the next time the level goes above Alarm 4.
7. To set Alarm 1, use the INCHES buttons to obtain the desired
set point on the CALIBRATION display, and then press the
ALARM SHUT DN or SHIFT-ALARM ST UP button followed
by the 1 button. When the operation is complete, repeat this
procedure for the other alarms, pressing 2, 3, and then 4 after
the ALARM button. If an alarm is not used it does not need
to be programmed.
8.
Make sure that the fiber from the sender bar is connected to
the gauge display, and plug the programmer plug into the
gauge display. Press the BAR button. The INCHES display
should show some inch reading, if it shows “no L” or “bad L’
check the fiber connection and the bar mode (1/3 or 1/6 inch).
NOTE: The black fiber optic cable connector MUST be shaded
from direct sunlight. See the information in the Description of
Keypad Buttons section for further information.
9. Measure the distance from the bottom of the tank to the
middle of the float, this is the bottom reading. Use the OFFSET
buttons to obtain this reading on the CALIBRATION display.
NOTE: The calibration offset is carried over when memory
locations are changed.
10. Press the PROG button to transfer the calibration to the
gauge.
11. When the operation is complete, unplug the programmer
from the gauge and verify gauge operation.
Copy one 810-PS2 gauge display to another:
1. Turn on the programmer.
2. Make sure the inch mode is correct.
Summary of Contents for SeeLevel ProSeries II 810-PS2
Page 30: ......