Part # JIBSM08 Rev.6 (08/04/09)
Page 43
TECHNICAL TROUBLESHOOTING
continued
Controller Displays “MOTOR OVER CURRENT” - Platen does not move at all
NO
YES
YES
NO
YES
YES
YES
NO
NO
YES
Check voltage of limit
switches. 5.6 VDC when
switch is Open, 0 VDC when
switches are closed.
Check for 120 volts at the
motor speed controller. Pins
3 & 4.
Possible broken connection
between the motor speed
controller and the terminal
block, terminal marked “SW”.
Replace defective Limit
Switch
Check for 120 - 140 VDC on
pins 1 & 2 or Motor Speed
Controller.
Check for positive
connection at input leads
of Linear Actuator.
Check for binded actuator by
disconnecting the upper
mounting pin, and manually
spinning actuator shaft.
Replace defective linear
actuator.
Replace defective Motor
Speed Controller.
From behind the unit
manually raise and lower the
platen by lifting up on the
platen arms.
Replace worn or damaged
components.
Controller Displays “MOTOR OVER CURRENT” - Platen stops and moves to lower limit
NO
YES
YES
Check voltage of upper limit
switches while platen is in the
upward movement.
Does Upper Limit
Switch change states of 5.6
VDC to 0 VDC?
Replace faulty Upper Limit
Switch.
Replace defective Motor
Speed Controller.
Summary of Contents for XE362S-2L
Page 48: ...Part JIBSM08 Rev 7 08 04 09 Page 48 ...
Page 50: ...Part JIBSM08 Rev 7 08 04 09 Page 50 XPRESS GRILL COMPLETE VIEW MODEL XG24 JIB XG24 JIB 1 ...
Page 67: ...Part JIBSM08 Rev 6 08 04 09 Page 67 ...
Page 68: ...Part JIBSM08 Rev 7 08 04 09 Page 68 XG36 JIB 2 ACTUATOR ASSEMBLY ASSEMBLY VIEW MODEL XG36 JIB ...
Page 87: ...Part JIBSM08 Rev 6 08 04 09 Page 87 ...
Page 88: ......