TECHNICAL TROUBLESHOOTING
continued
Master Power (ON / OFF) Switch turned ON - Power Light in On - Grill is not heating
YES
YES
NO
YES
YES
NO
NO
NO
YES
NO
Controller display
reads “OFF”
High voltage power
cord(s) unplugged
High voltage circuit breaker at
service panel is OFF or tripped
Check for 120 VAC at terminal
block between LIM & NEUT
Test continuity on contactor
coil between LIM & NEUT
Replace defective contactor
Press the MENU SELECT
button.
Reconnect power supply
Reset circuit breaker
Disconnect power supply
and perform continuity test
on terminals of high limit
in upper platen
Replace defective high limit