background image

Part # P143 (11/10/08)

Page 12

CONVERSION INSTRUCTIONS

Servicing must be carried out by a competent person in 

accordance with the law .

WARNING:  Turn off the gas supply to the appliance at the 

service cock before commencing any servicing work .

IMPORTANT:  Test for gas soundness on completion of any 

servicing work .

The following instructions are intended to describe the 

operations necessary to convert equipment from operation 

on one gas family to that of another .

1 .  Ensure that all of the parts necessary to make the 

conversion have been supplied as follows:

a .  Injector fittings (One required for each main burner) .
b .  Pilot injector fittings (One required per pilot burner) .
c .  Gas adjustment label (One required per unit) .

If any of the required parts are missing, contact your Garland 

dealer before attempting to carry out the conversion .

NOTE: Conversion kits supplied for G31 gas will contain 

redundant fittings and markings covering both 37 mbar & 50 

mbar gas supplies .

2 .  Remove the burners following the instructions given in 

this manual .

3 .  Replace each injector fitting with the new fitting that is 

supplied .

NOTE: Before doing so, refer to Table D (Table G for Australian 

Models) in this manual to ensure that the correct injector has 

been supplied for the gas supply being converted to .

4 .  Replace each pilot injector fitting with the new fitting 

supplied .

Ensure that you have the correct pilot injector before 

replacing .

Upon completion of all the above operations, follow the 

section in the manual on “Commissioning” and ensure 

that the setting pressure and all burner flame settings are 

adjusted accordingly .

Continuous product improvement is a Garland policy, 

therefore specifications and design are subject to change 

without notice .

Summary of Contents for MSTSR16-280

Page 1: ...Phone 570 636 1000 Fax 570 636 3903 GARLAND COMMERCIAL RANGES LTD 1177 Kamato Road Mississauga Ontario L4W 1X4 CANADA Phone 905 624 0260 Fax 905 624 5669 Enodis U Swallowfiel Telephone Fax 081 84 Part...

Page 2: ...d expose you to airborne particles of glass wool ceramic fibers Inhalation of airborne particles of glass wool ceramic fibers is known to the state of California to cause cancer Operation of this prod...

Page 3: ...NTRODUCTION 6 Uncrating 6 Product Application 6 Optional Extras 6 Rating Plate 6 INSTALLATION 7 General Installation 7 Clearances 7 Siting 7 Ventilation Air 7 Statutory Regulations 7 COMMISSIONING 8 B...

Page 4: ...64 mm wide x 1089 mm high infra red restaurant range mount salamander MSTSR16 864 mm wide x 1089 mm high infra red heavy duty range mount salamander Suffix Definitions MST SRC SR16 280 SR16 SRC Counte...

Page 5: ...ominal Heat Input Gross kW BTU HR MJ HR kW BTU HR MJ HR MSTSRC 9 23 31 500 33 23 8 35 28 500 30 1 MSTSR16 9 23 31 500 33 23 8 35 28 500 30 1 Table D Setting Pressure Injector Size MODEL SECTION G20 20...

Page 6: ...Wherever possible avoid overheating idle equipment as this is the primary cause for increased service cost Regular Maintenance Ensures Peak Performance Uncrating Check crate for possible damage sustai...

Page 7: ...able of adequately supporting the weight of the appliance and any ancillary equipment Refer to table A for weight specifications Any openings in the wall behind or beside the appliance must be sealed...

Page 8: ...able it to be isolated in an emergency Wherever practical this shall be located either outside the kitchen or near to an exit in a readily accessible position Where it is not practical to do this an a...

Page 9: ...it counter clockwise to the full flame position thus lighting the main burner 5 For low flame or simmer push the tap in and turn it counter clockwise to the low flame position 6 To shut the burner off...

Page 10: ...ue may be removed with a lightweight non metallic scouring pad 4 Clean out grease drawer and wash thoroughly in hot soapy water Dry thoroughly Stainless Steel Stainless steel should be cleaned using a...

Page 11: ...g the pilot REPLACEMENT OF PARTS WARNING Turn off the gas supply to the appliance at the service cock before commencing any servicing work IMPORTANT Test for gas soundness on completion of any servici...

Page 12: ...your Garland dealer before attempting to carry out the conversion NOTE Conversion kits supplied for G31 gas will contain redundant fittings and markings covering both 37 mbar 50 mbar gas supplies 2 Re...

Page 13: ...hermocouple connection Tighten connection Faulty thermocouple Replace thermocouple Faulty flame safety device Replace flame safety device Low millivolt output on open circuit test Pilot flame too smal...

Page 14: ...Part P143 11 10 08 Page 14...

Page 15: ...Part P143 11 10 08 Page 15...

Page 16: ......